Tramex HIPP1

Tramex Hygro-i2 Relative Humidity Probe HIPP1 Instruction Manual

Model: HIPP1

1. Уводзіны

The Tramex Hygro-i2 Relative Humidity Probe is an advanced, reusable sensor designed for accurate measurement of relative humidity, temperature, and dew point in concrete and cementitious floors. This probe facilitates in-situ RH testing in compliance with ASTM F2170 standards, making it suitable for professionals in flooring, flood and water damage restoration, and indoor air quality assessment.

The Hygro-i2 probe offers rapid acclimation and temperature response, ensuring precise and reliable data collection even in environments with high relative humidity (above 90%). Its robust construction contributes to longevity and reusability, providing a cost-effective solution for moisture detection.

Tramex Hygro-i2 Relative Humidity Probe

Image 1.1: The Tramex Hygro-i2 Relative Humidity Probe, a grey cylindrical sensor with a perforated cap.

2. Components and Compatibility

The Hygro-i2 probe is designed for integration with specific Tramex moisture meters and data loggers. To operate the probe, an electronic interface cable is required.

2.1 Неабходныя аксэсуары

  • Electronic Interface Cable (RHIE2B): This cable connects the Hygro-i2 probe to compatible Tramex devices.

2.2 сумяшчальныя прылады

The Hygro-i2 probe must be used in conjunction with one of the following Tramex devices:

  • Tramex Concrete Moisture Encounter CMEX5 (Non-destructive moisture meter)
  • Tramex Moisture Encounter MEX5 (Non-destructive moisture meter)
  • Tramex Feedback Datalogger DL-RHTX
Tramex Hygro-i2 Probe integration with Tramex CMEX5, MEX5, and DL-RHTX devices

Image 2.1: The Hygro-i2 probe shown with compatible Tramex devices: Concrete Moisture Encounter CMEX5, Moisture Encounter X5 (MEX5), and Feedback Datalogger (DL-RHTX).

3. Setup and Installation for ASTM F2170 Testing

Proper setup is crucial for accurate in-situ relative humidity testing in concrete floors according to ASTM F2170.

3.1 Preparing the Concrete Slab

  1. Свідраваць адтуліну: Drill a hole into the concrete slab to a depth of 40% of the slab thickness if drying from one side, or 20% if drying from two sides. The hole diameter should be appropriate for the probe sleeve.
  2. Clean Hole: Thoroughly clean the drilled hole to remove all debris and dust.
  3. Insert Sleeve: Insert a plastic sleeve (not included with probe) into the cleaned hole. Ensure the sleeve is flush with the concrete surface.
  4. Cap Sleeve: Place a cap over the sleeve to prevent moisture ingress and allow the hole to acclimate.

3.2 Probe Acclimation

Allow the drilled hole and sleeve to acclimate to the ambient conditions for a minimum of 24 hours before inserting the Hygro-i2 probe. This ensures that the air within the hole reaches equilibrium with the concrete's internal moisture conditions.

3.3 Падключэнне зонда

  1. Кабель падлучэння: Attach the RHIE2B Electronic Interface Cable to the Hygro-i2 probe. Ensure a secure connection.
  2. Connect to Meter: Plug the other end of the RHIE2B cable into the designated port on your compatible Tramex moisture meter (CMEX5, MEX5) or data logger (DL-RHTX).
Connecting the Tramex Hygro-i2 probe to its interface cable

Малюнак 3.1: Крупны план view showing the connection point between the Hygro-i2 probe and its electronic interface cable.

4. Інструкцыя па эксплуатацыі

Once the concrete hole has acclimated and the probe is connected, you can proceed with taking measurements.

4.1 Вымярэнне

  1. Уставіць зонд: Remove the cap from the acclimated sleeve. Carefully insert the Hygro-i2 probe into the sleeve until it rests securely at the bottom.
  2. Power On Meter: Turn on your connected Tramex moisture meter or data logger.
  3. Чытанне дадзеных: The device will display the relative humidity, temperature, and dew point readings. Allow a few moments for the readings to stabilize. The Hygro-i2 probe is known for its fast acclimation and temperature response, minimizing downtime between tests.
  4. Даныя запісу: Record the stable readings as required for your project documentation.
Tramex Concrete Moisture Encounter displaying readings with Hygro-i2 probe connected

Image 4.1: A Tramex Concrete Moisture Encounter meter displaying relative humidity, temperature, and dew point readings, with the Hygro-i2 probe connected.

4.2 Асноўныя характарыстыкі для эксплуатацыі

  • Fast Acclimation: The probe quickly stabilizes in diverse environments, reducing waiting times.
  • Высокая дакладнасць: Provides precise measurements, even at high relative humidity levels (>90%).
  • Шырокі дыяпазон вымярэнняў: Capable of measuring from 0% to 100% RH.
Diagram illustrating fast acclimation and temperature response of the Hygro-i2 probe

Image 4.2: Visual representation of the Hygro-i2 probe's fast acclimation and temperature response, highlighting quick stabilization and enhanced workflow efficiency.

5. Тэхнічнае абслугоўванне

Proper maintenance ensures the longevity and continued accuracy of your Hygro-i2 probe.

5.1 Ачыстка зонда

After each use, gently wipe the probe with a clean, dry, soft cloth. Avoid using abrasive materials or chemical solvents, as these can damage the sensor. Ensure no debris obstructs the sensor openings.

5.2 Захоўванне

Store the Hygro-i2 probe in a clean, dry environment, preferably in its original packaging or a protective case, when not in use. This protects the sensor from dust, physical damage, and extreme environmental conditions.

5.3 Sensor Protection

The probe features protected sensor openings to minimize damage. However, avoid direct contact with liquids or harsh chemicals. Do not attempt to disassemble the probe, as this will void any warranty and may cause permanent damage.

Diagram highlighting robust and reusable design features of the Hygro-i2 probe

Image 5.1: Features of the Hygro-i2 probe's robust and reusable design, including durable construction, low drift rates, and protected sensor openings.

6. Выпраўленне непаладак

If you encounter issues with your Hygro-i2 probe, consider the following common problems and solutions.

  • Няма паказанняў або паказанні няправільныя:
    • Ensure the RHIE2B interface cable is securely connected to both the probe and the Tramex meter.
    • Check the battery level of your Tramex meter.
    • Verify that the probe is fully inserted into the concrete sleeve and has had sufficient acclimation time (minimum 24 hours).
    • Inspect the probe's sensor openings for any obstructions or damage.
  • Няправільныя паказанні:
    • Confirm the concrete hole has acclimated for the recommended period.
    • Ensure the probe is clean and free from debris.
    • If consistently inaccurate, the probe may require recalibration or replacement. Contact Tramex support for assistance.
  • Probe Not Recognized by Meter:
    • Ensure your Tramex meter is compatible with the Hygro-i2 probe (CMEX5, MEX5, DL-RHTX).
    • Check the connection of the RHIE2B cable.
    • Restart the Tramex meter.

For persistent issues, refer to the specific instruction manual of your Tramex moisture meter or data logger, or contact Tramex customer support.

7. Тэхнічныя характарыстыкі

АсаблівасцьСпецыфікацыя
Нумар мадэліHIPP1
Дыяпазон вымярэнняў0% да 100% адноснай вільготнасці (RH)
АдпаведнасцьASTM F2170
Час водгукуFast acclimation and temperature response
Шматразовае выкарыстаннеШматразовы дызайн
Dimensions (Probe)Прыблізна 6.3 х 4 х 1 цалі (памеры ўпакоўкі)
Weight (Probe)Прыблізна 0.01 унцый (вага ўпакоўкі)
ВытворцаTramex

8. Гарантыя і падтрымка

For information regarding product warranty, technical support, or service, please contact Tramex directly. Details can typically be found on the official Tramex webна сайце або праз дакументацыю аб куплі вашага прадукту.

вытворца: Tramex

Для атрымання дадатковай дапамогі наведайце Tramex Store on Amazon or the official Tramex webсайт.