TRUPER BOS-1LM

Truper BOS-1LM 1 HP Submersible Bullet Pump for Clean Water User Manual

Model: BOS-1LM

1. Уводзіны

This manual provides essential information for the safe and efficient operation of your Truper BOS-1LM 1 HP Submersible Bullet Pump. This pump is designed for extracting clean water from wells, springs, or for irrigation systems. It features a durable stainless steel body, a copper-wound motor for extended life, and an integrated electrical control unit.

2. Інструкцыі па тэхніцы бяспекі

Read all safety warnings and instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Электрабяспека: Ensure the power supply matches the pump's specifications. Always disconnect power before performing any maintenance or installation. Do not operate the pump with damaged cables or plugs.
  • Якасць вады: This pump is designed for clean water only. Do not use it for flammable liquids, corrosive chemicals, or water containing large abrasive particles.
  • Апусканне ў ваду: The pump must be fully submerged during operation to prevent overheating. Ensure adequate water level.
  • Ўстаноўка: Securely install the pump using appropriate suspension methods. Ensure all connections are watertight.
  • Дзеці і хатнія жывёлы: Keep children and pets away from the pump and its operating area.
  • Цеплавая абарона: The pump is equipped with a thermal protector to prevent motor damage from overheating or blockage. If the pump stops unexpectedly, allow it to cool down before restarting and investigate the cause.

3. Кампаненты прадукту

Familiarize yourself with the main components of your Truper BOS-1LM pump:

Diagram of Truper BOS-1LM submersible pump components

Малюнак 3.1: Labeled diagram of the Truper BOS-1LM pump and its control unit. Key components include: Suspension Eyelets (Ojos de suspensión), 2.5 mm Suction Holes (Orificios de succión de 2.5 mm), Stainless Steel Casing (Carcasa de acero inoxidable), 38 mm Discharge Connection (Conexión de descarga de 38 mm), Power Control Box (Caja de control de encendido), On/Off Switch (Interruptor encendido/apagado), and Overload Protection Switch (Interruptor de protección de sobrecarga).

4. Настройка

  1. Распакаванне: Carefully remove the pump and all accessories from the packaging. Inspect for any damage.
  2. Падвеска: Attach a strong rope or cable to the suspension eyelets at the top of the pump. This will be used to lower and retrieve the pump. Do not use the power cable for suspension.
  3. Разраднае злучэнне: Connect a 38 mm (1.5 inch) discharge hose or pipe to the pump's discharge connection. Ensure a secure and leak-free connection.
  4. Control Unit Placement: Mount the electrical control unit in a dry, accessible location, away from direct water exposure.
  5. Электрычнае падключэнне: Connect the pump's power cable to the control unit. Then, connect the control unit to a suitable grounded power outlet. Ensure the power supply matches the pump's voltagе і патрабаванні да частоты.
  6. Lowering the Pump: Slowly lower the pump into the water source using the suspension rope. Ensure the pump is fully submerged and rests vertically, not touching the bottom or sides of the well/tank.
Dimensions of Truper BOS-1LM submersible pump

Малюнак 4.1: The Truper BOS-1LM pump measures 71 cm in height and 9 cm in diameter, indicating its compact 'bullet' design suitable for narrow spaces.

5. Інструкцыя па эксплуатацыі

Once the pump is properly installed and submerged, follow these steps for operation:

  1. Уключэнне: Ensure the overload protection switch on the control unit is in the 'ON' position. Press the 'ON' button on the control unit to start the pump.
  2. Манітор патоку: Observe the water flow from the discharge. The pump should begin pumping water immediately.
  3. Выключэнне: To stop the pump, press the 'OFF' button on the control unit.
  4. Крывая прадукцыйнасці: Refer to the performance curve to understand the pump's flow rate (L/min) at different discharge heights (m). This helps in optimizing usage for your specific needs.
Truper BOS-1LM pump operation diagram and performance curve

Малюнак 5.1: This image illustrates the pump's operation, showing it submerged in a well, pumping water with increased pressure. It also includes a performance curve graph, indicating the recommended use area and the relationship between pumping height (Altura in meters) and flow rate (Flujo in L/min) for the BOS-1LM model.

6. Тэхнічнае абслугоўванне

Рэгулярнае тэхнічнае абслугоўванне забяспечвае даўгавечнасць і аптымальную прадукцыйнасць вашага помпы.

  • Ачыстка фільтра: The pump has a filtering grid for particles up to 1.5 mm. Periodically inspect and clean the suction holes and filter to prevent blockages and maintain efficient flow.
  • агляд: Regularly inspect the pump body, power cable, and discharge hose for any signs of wear, damage, or corrosion. Replace damaged components immediately.
  • захоўванне: If the pump will not be used for an extended period, clean it thoroughly, drain all water, and store it in a dry, frost-free location.
  • Тэрмічны пратэктар: The thermal protector automatically shuts off the motor if it overheats. If this occurs, disconnect power, allow the pump to cool, and check for blockages or low water levels before restarting.

7. Выпраўленне непаладак

Перад тым, як звяртацца ў службу падтрымкі, паўторнаview гэтыя распаўсюджаныя праблемы і рашэнні:

праблемаМагчымая прычынаРашэнне
Помпа не запускаеццаNo power; Thermal protector tripped; Motor blockageCheck power supply and connections; Allow pump to cool and reset; Inspect for and clear any blockages.
Слабы паток або яго адсутнасцьLow water level; Clogged filter/suction; Kinked or blocked discharge hoseEnsure pump is fully submerged; Clean suction holes and filter; Check and clear discharge hose.
Помпа працуе, але вады нямаAir lock; Pump not fully submergedRaise and lower pump slightly to release air; Ensure full submersion.
Празмерная вібрацыя/шумPump not properly suspended; Debris in impellerAdjust suspension; Disconnect power and inspect impeller for debris.

8. Тэхнічныя характарыстыкі

Technical specifications for the Truper BOS-1LM pump:

АсаблівасцьСпецыфікацыя
Нумар мадэліБОС-1ЛМ
Магутнасць1 HP (750 Вт)
МатэрыялStainless Steel, Copper
Крыніца харчаванняЭлектрычны кабель
Максімальная хуткасць патоку6000 Liters per hour (9600 L/h on box, using 6000 L/h from specs)
Max Height (Head)40 метраў
Particle Filter SizeДа 1.5 мм
Памеры прадукту (Д х Ш х У)9 х 9 х 71 см
Вага13.72 кг
Разраднае злучэнне38 мм

9. Гарантыя і падтрымка

For warranty information or technical support, please refer to the documentation included with your purchase or visit the official TRUPER webсайт. Захоўвайце чэк аб куплі як пацвярджэнне пакупкі ў выпадку любых гарантыйных прэтэнзій.

TRUPER Contact Information: