Уводзіны
This manual provides detailed instructions for the proper use and maintenance of your Apera Instruments Salt20 Salinity Tester Kit. The Salt20 is designed for professional salinity measurement in various water solutions, including pools, spas, agriculture, and environmental monitoring.
For optimal performance and longevity of your device, please read this manual thoroughly before operation.

The Apera Instruments Salt20 Salinity Tester is suitable for a wide range of applications including hydroponics, pools, and drinking water analysis.
Тэхніка бяспекі
Важная інфармацыя па бяспецы
- Always handle the device with care to prevent damage to the sensor.
- Do not immerse the entire meter in water beyond the specified IP67 waterproof rating.
- Keep calibration solutions and the device out of reach of children.
- Калі прылада не выкарыстоўваецца, захоўвайце яе ў прахалодным сухім месцы.
- Ensure the battery compartment is sealed properly to maintain water resistance.
Прадукт скончаныview
Камплектуючыя

The Salt20 Salinity Tester Kit includes the meter, calibration solution, AAA batteries, and a lanyard, all housed in a portable carrying case.
The Apera Instruments Salt20 Salinity Tester Kit includes:
- Salt20 Salinity Tester
- 1 bottle of calibration solution (12.88 mS/cm, equivalent to 6.44 ppt)
- AAA batteries (pre-installed or included)
- Шнурок
- Партатыўны футляр для пераноскі
Асноўныя характарыстыкі
- Высокая дакладнасць: Apera's unique platinum black sensor (BPB) ensures high accuracy in a wide-range salinity measurement (0 to 10.0 ppt).
- Easy Auto Calibration: 1-point auto calibration with auto buffer recognition.
- Аўтаматычная тэмпературная кампенсацыя (ATC): 0-50°C ATC for precise readings.
- Празрысты ВК-дысплей: Large LCD with dual display of salinity (ppt) and temperature (°C/°F), including reminders for stable readings and completed calibrations.
- Воданепранікальны дызайн: IP67 water-resistant and floatable for durability.
- Доўгі тэрмін службы батарэі: Up to 1000 hours of operation powered by AAA batteries.
- Самадыягностыка: With out-of-range and low battery warnings.
Sensor Technology

The Salt20 features Apera's unique Brush-Resistant Platinum Black (BPB) sensor, designed for high accuracy and consistency in wide-range salinity testing.
Дэталі ВК-дысплея

The clear LCD display provides simultaneous readings for salinity (ppt) and temperature, along with indicators for stable readings and successful calibration.
Аксэсуары

A lanyard is included for convenient and secure use of the Salt20 Salinity Tester.

The complete test kit comes in a rugged carrying case for protection and portability.
Настройка
Ўстаноўка акумулятара
The Salt20 Salinity Tester is powered by 4 AAA batteries.
- Unscrew the battery cap at the top of the meter.
- Insert the AAA batteries according to the polarity indicators (+/-).
- Securely screw the battery cap back on to ensure the waterproof seal.
Першапачатковая падрыхтоўка
- Зніміце ахоўны каўпачок з датчыка.
- Rinse the sensor with distilled water and gently shake off excess water.
- The meter is now ready for calibration or measurement.
Інструкцыя па эксплуатацыі
Базавае вымярэнне
- Уключыць: Short press the MEAS button to turn on the meter.
- Immerse Sensor: Dip the sensor into the sample solution, ensuring the solution covers the sensor completely. Stir gently to remove air bubbles.
- Вымярэнне зчытаных дадзеных: Wait for the smiley face icon to appear and remain stable on the LCD, indicating a stable reading. Record the salinity (ppt) and temperature (°C/°F) values.
- Выключыць: Long press the MEAS button to turn off the meter.
Пераключэнне адзінак
To switch between °C and °F, with the meter turned off, long press the CAL button until the unit changes.
Афіцыйнае відэа пра прадукт
Watch this official video from Apera Instruments for a visual guide on using the Salt20 Salinity Tester Kit. This video provides an overview характарыстык прадукту і асноўных дзеянняў.
Каліброўка
1-Point Auto Calibration
The Salt20 Salinity Tester uses a 1-point auto calibration process with auto buffer recognition. It is recommended to calibrate the meter regularly for accurate results, especially before critical measurements or if the meter has not been used for a long time.

The Salt20 Salinity Tester features effortless single-button auto calibration with auto buffer recognition, simplifying the calibration process.
- Падрыхтуйце раствор: Pour a small amount of the 12.88 mS/cm (6.44 ppt) calibration solution into a clean beaker.
- Увайдзіце ў рэжым каліброўкі: With the meter turned on, short press the CAL button. The display will show "CAL" and the calibration value.
- Immerse Sensor: Dip the sensor into the calibration solution. Stir gently.
- Wait for Stability: The meter will automatically recognize the calibration solution. Wait for the smiley face icon to appear and remain stable. The calibration success symbol (M) will also appear.
- Exit Calibration: Short press the MEAS button to exit calibration mode and return to measurement mode.
Заўвага: Always use fresh calibration solution for each calibration. Do not pour used solution back into the bottle.
Тэхнічнае абслугоўванне
Ачыстка датчыка
The BPB (Brush-Resistant Platinum Black) sensor is robust but requires proper cleaning to maintain accuracy.
- After each use, rinse the sensor thoroughly with distilled or deionized water.
- If there is visible contamination, gently brush the sensor with a soft brush (like a soft toothbrush) while rinsing.
- For stubborn deposits, soak the sensor in a mild detergent solution for 10-15 minutes, then rinse thoroughly.
- ніколі wipe the sensor with abrasive materials or apply excessive force, as this can damage the platinum black coating.
Захоўванне
For long-term storage, ensure the sensor is clean and dry. Replace the protective cap. Store the meter in its carrying case in a cool, dry place.
Ліквідацыю непаладак
Агульныя праблемы і рашэнні
| выпуск | Магчымая прычына | Рашэнне |
|---|---|---|
| Няправільныя паказанні | Sensor dirty; Calibration needed; Expired calibration solution | Clean sensor; Perform calibration; Use fresh calibration solution |
| No Display / Meter Won't Turn On | Разраджаныя батарэйкі; няправільная ўстаноўка батарэй | Замяніце батарэйкі; праверце палярнасць батарэек |
| "Out-of-Range" Warning | Salinity level exceeds 10.0 ppt | The meter's range is 0-10.0 ppt. For higher ranges, a different meter is required. |
| Павольны адказ | Датчык патрабуе ачысткі | Clean the sensor thoroughly |
Тэхнічныя характарыстыкі
Тэхнічныя характарыстыкі
| Параметр | Каштоўнасць |
|---|---|
| Salinity Range | 0 - 10.0 ppt |
| Salinity Accuracy | ± 1% ФС |
| Дыяпазон тэмператур | 0 - 50°C (32 - 122°F) |
| Тэмпературная кампенсацыя | Automatic (0-50°C) |
| Каліброўка | Auto 1-point |
| Электразабеспячэнне | 4 х ААА батарэі |
| Тэрмін службы батарэі | Да 1000 гадзін |
| Рэйтынг воданепранікальнасці | IP67 (Dust-proof and Water-proof, Floatable) |
| Аўтаматычнае выключэнне | 8 minutes of no operation |
| Памеры | 7.01 х 1.61 х 1.18 цалі |
| Вага | 3.8 унцыі |
Гарантыя і падтрымка
Інфармацыя аб гарантыі
Apera Instruments provides a limited warranty for its products. Please refer to the official Apera Instruments webна сайце або ў гарантыйным талоне, які ўваходзіць у камплект пастаўкі прадукту, каб даведацца пра канкрэтныя гарантыйныя ўмовы.
Падтрымка кліентаў
For technical assistance, troubleshooting, or inquiries about replacement parts and accessories, please contact Apera Instruments customer support.
Webсайт: www.aperainst.com
электронная пошта: Refer to your product documentation for specific contact email.
тэлефон: Refer to your product documentation for specific contact phone number.