This manual provides essential instructions for the safe and efficient use of your Techly Professional 023189 Vertical Rack Power Strip. Please read this manual thoroughly before installation and operation, and retain it for future reference.
The Techly Professional 023189 is a 12-outlet vertical rack-mountable power distribution unit (PDU) designed for professional environments. It features Schuko outlets, a thermal-magnetic circuit breaker for overload protection, and a durable aluminum and black finish.
Інфармацыя па бяспецы
WARNING: To reduce the risk of electric shock, fire, or injury, always follow basic safety precautions when using electrical products.
- Do not exceed the maximum load capacity of 3.5 kW (16 A, 250 V AC).
- Гэты прадукт прызначаны толькі для выкарыстання ў памяшканнях.
- Do not connect multiple power strips together.
- Ensure the power strip is properly grounded.
- Do not open or modify the device. Refer all servicing to qualified personnel.
- Трымаць далей ад вады і асяроддзяў з падвышанай вільготнасцю.
- Ensure proper ventilation when installed in a rack.
Змест пакета
Праверце наяўнасць усіх прадметаў і іх цэласнасць:
- Techly Professional 023189 Vertical Rack Power Strip (12 Schuko outlets)
- Кіраўніцтва карыстальніка
Image: The product packaging box, labeled "TECHLY PROFESSIONAL 19" Power Distribution Unit".
Прадукт скончаныview
The Techly Professional 023189 is a robust power distribution unit designed for vertical mounting in 19-inch server racks. It provides 12 Schuko outlets for connecting various electrical devices.
Выява: Поўная view of the Techly Professional 023189 power strip, showing 12 Schuko outlets, the circuit breaker, and mounting brackets.
Асноўныя характарыстыкі:
- 12 Schuko (IEC60884) outlets angled at 45°
- Integrated thermal-magnetic circuit breaker for overload protection
- Vertical rack-mountable design
- 3-meter power cable with angled Schuko plug
- Durable aluminum and black finish
- Maximum load capacity: 3.5 kW (16 A, 250 V AC)
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in an open position, revealing the blue switch and "I ON / O OFF" markings.
Выява: Падрабязны view of the angled Schuko power plug, which connects the power strip to the main power source.
Настройка і ўстаноўка
- Unpack the Power Strip: Асцярожна дастаньце падаўжальнік з упакоўкі. Праверце яго на наяўнасць пашкоджанняў.
- Выберыце месца ўстаноўкі: Select a suitable vertical location within a standard 19-inch server rack. Ensure there is adequate space for cable management and ventilation.
- Mount the Power Strip: Use appropriate rack screws (not included) to securely fasten the power strip's mounting brackets to the rack rails.
- Падключэнне да крыніцы харчавання: Plug the power strip's angled Schuko plug into a properly grounded wall outlet or UPS.
- Падключыце прылады: Plug your electrical devices into the 12 Schuko outlets on the power strip. Ensure the total power consumption does not exceed 3.5 kW.
Выява: Частковая view of the power strip, highlighting the mounting brackets on the side, designed for vertical installation in a server rack.
Аперацыя
- Уключэнне: Locate the thermal-magnetic circuit breaker on the power strip. Flip the switch to the "I ON" position to supply power to the outlets.
- Абарона ад перагрузкі: If the total current drawn by connected devices exceeds 16 A, the thermal-magnetic circuit breaker will automatically trip to the "O OFF" position, cutting power to prevent damage.
- Выключэнне: To cut power to all connected devices, flip the circuit breaker switch to the "O OFF" position.
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in a closed position, covering the blue switch.
Тэхнічнае абслугоўванне
- Уборка: Disconnect the power strip from the main power source before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.
- агляд: Periodically inspect the power strip, cable, and plug for any signs of wear, damage, or overheating. If any damage is observed, discontinue use immediately and replace the unit.
- Вентыляцыя: Ensure that the power strip and connected devices have adequate airflow to prevent overheating.
Ліквідацыю непаладак
| праблема | Магчымая прычына | Рашэнне |
|---|---|---|
| No power to outlets. | Спрацаваў аўтаматычны выключальнік. | Reduce the load by unplugging some devices, then reset the circuit breaker by flipping it to "I ON". |
| No power to outlets. | Падаўжальнік не падключаны да сеткі. | Ensure the power strip's plug is securely inserted into a live wall outlet. |
| Devices not functioning. | Device-specific issue. | Check the individual device's power connection and functionality. |
Калі праблема не знікне пасля спробы гэтых рашэнняў, звярніцеся ў службу падтрымкі кліентаў.
Тэхнічныя характарыстыкі
- мадэль: I-CASE STRIP-12SH
- Марка: Techly Professional
- Разеткі: 12 x Schuko (Type F) 45° angled with earth
- Уваходны штэкер: Angled Schuko (Type F)
- Кабель: H05VV-F 3G 2.5 мм²
- Даўжыня кабеля: 3 метраў
- Рэйтынг электрычнасці: 16 А, 250 В пераменнага току
- Максімальная грузападымальнасць: 3.5 кВт
- Памеры (Д х Ш х У): 735 x 62 x 44 mm (73.5L x 6.2W cm)
- Вага: 1795 грам
- матэрыял: Aluminum (body), Black (finish)
- асаблівасць: Mountable (vertical rack installation)
- Сертыфікаты: CE, WEEE
Інфармацыя аб гарантыі
Information regarding specific warranty terms is not available in the provided product details. Please refer to the retailer's return policy or contact Techly Professional directly for warranty details.
Палітыка вяртання: The buybox winner indicates a 30-day return policy (refund/replacement).
Падтрымка кліентаў
For technical assistance or further inquiries, please visit the official Techly webсайт або звярніцеся да прадаўца.