Geko G02662

Geko G02662 Freezing Point Refractometer Instruction Manual

1. Уводзіны

This manual provides detailed instructions for the proper use, calibration, and maintenance of your Geko G02662 Freezing Point Refractometer. This precision optical instrument is designed to measure the freezing point of automotive coolants (ethylene glycol and propylene glycol based) and battery fluid condition. Please read this manual thoroughly before operating the device to ensure accurate results and prolong its lifespan.

2. Інфармацыя па бяспецы

  • Always handle the refractometer with care. Avoid dropping or subjecting it to strong impacts.
  • Do not immerse the instrument in water or other liquids.
  • Avoid direct exposure of the prism to strong light sources, as this may damage the optical components.
  • When handling automotive fluids, wear appropriate personal protective equipment (e.g., gloves, eye protection) and follow manufacturer safety guidelines for the fluids being tested.
  • Трымайце інструмент у месцах, недаступных для дзяцей.

3. Змесціва ўпакоўкі

Праверце наяўнасць усіх прадметаў у камплекце:

  • Geko G02662 Refractometer
  • Піпетка
  • Mini-screwdriver (for calibration)
  • Анучка для чысткі
  • Кейс для захоўвання
  • Інструкцыя па эксплуатацыі (гэты дакумент)

4. Прадукт скончыўсяview

Familiarize yourself with the components of the Geko G02662 Refractometer:

Geko G02662 Freezing Point Refractometer side view

Малюнак 1: Збоку view of the Geko G02662 Refractometer. This image displays the overall structure of the device, including the eyepiece, main body, and prism assembly.

Geko G02662 Refractometer prism and cover plate

Малюнак 2: Close-up of the prism and cover plate. The sample is applied to the main prism, which is then covered by the transparent plate.

Geko G02662 Refractometer eyepiece view

Малюнак 3: View of the eyepiece. The user looks through this end to read the measurement scale.

  1. Акуляр: Прывыклі view the measurement scale. Rotate to adjust focus.
  2. Гумавая ручка: Provides a secure hold.
  3. Асноўны корпус: Contains the optical system.
  4. Calibration Screw: Used to adjust the zero point (under a cap).
  5. Прызма: The surface where the sample is placed.
  6. Накрыўка: Covers the sampле на прызме.

5. Настройка

Before first use, or if the focus appears blurry:

  1. Hold the refractometer towards a light source.
  2. Паглядзіце ў акуляр.
  3. Rotate the eyepiece (part 1 in Figure 1) until the scale is clear and in sharp focus.

6. Інструкцыя па эксплуатацыі

Follow these steps to take an accurate measurement:

  1. Clean the Prism: Ensure the prism (part 5) and cover plate (part 6) are clean and dry using the provided cleaning cloth.
  2. Ужыць Сampль: Open the cover plate. Using the pipette, place 2-3 drops of the liquid to be tested onto the main prism.
  3. Close Cover Plate: Gently close the cover plate so that the liquid spreads evenly across the entire surface of the prism without air bubbles.
  4. Wait for Temperature Equalization: Allow approximately 30 seconds for the sample to equalize to the instrument's temperature. This is crucial for accurate readings.
  5. Вымярэнне зчытаных дадзеных: Hold the refractometer towards a light source and look through the eyepiece. The boundary line between the blue and white fields will indicate the measurement on the appropriate scale.
  6. Ачыстка пасля выкарыстання: Immediately after each measurement, clean the prism and cover plate thoroughly with a damp cloth, then dry with the cleaning cloth. Failure to do so can lead to inaccurate readings and damage to the prism.

7. Каліброўка

Calibration should be performed before first use, after cleaning, or if you suspect inaccurate readings. Use distilled water for calibration.

  1. Ensure the refractometer is at room temperature (20°C / 68°F).
  2. Clean the prism and cover plate thoroughly.
  3. Place 2-3 drops of дыстыляванай вады onto the prism. Close the cover plate.
  4. Wait 30 seconds for temperature equalization.
  5. Look through the eyepiece. The boundary line should align with the 'WATERLINE' or '0' mark on the scale.
  6. If it does not, use the provided mini-screwdriver to turn the calibration screw (part 4, usually under a small cap) until the boundary line aligns perfectly with the 'WATERLINE' or '0' mark.
  7. Clean and dry the prism and cover plate.

8. Тэхнічнае абслугоўванне і догляд

  • Уборка: Always clean the prism and cover plate immediately after use with a soft, damp cloth, then dry with the cleaning cloth. Do not use abrasive materials or solvents.
  • захоўванне: Store the refractometer in its protective case in a dry, cool, and dust-free environment when not in use. Avoid direct sunlight or extreme temperatures.
  • Пазбягайце пашкоджанняў: Do not touch the prism surface with your fingers or any hard objects.

9. Выпраўленне непаладак

праблемаМагчымая прычынаРашэнне
Blurry scaleEyepiece out of focusRotate the eyepiece to adjust focus.
Няправільныя паказанніInstrument not calibrated; Prism dirty; Insufficient sample; Air bubbles in sample; Temperature difference.Calibrate the instrument; Clean the prism; Apply sufficient sample (2-3 drops); Ensure no air bubbles; Allow sample to equalize temperature.
Boundary line not visibleInsufficient light; Sample too dark/opaque.Point towards a brighter light source; Ensure sample is clear enough for measurement.

10. Тэхнічныя характарыстыкі

  • Нумар мадэлі: Geko G02662
  • вытворца: Firma Handlowa GEKO
  • Памеры ўпакоўкі: 35 х 35 х 15 см
  • Вага: 220 г
  • Дыяпазон вымярэнняў: Typically for Ethylene Glycol, Propylene Glycol, and Battery Fluid (specific scales visible through eyepiece).
  • Аўтаматычная тэмпературная кампенсацыя (ATC): Yes (for accurate readings regardless of ambient temperature).

11. Гарантыя і падтрымка

Каб атрымаць інфармацыю аб гарантыі і тэхнічнай падтрымцы, звярніцеся да дакументацыі, прадстаўленай у месцы пакупкі, або звярніцеся да прадаўца. Захоўвайце чэк аб куплі як пацверджанне пакупкі.

Ask a question about this manual