Apera Instruments AI532
Apera Instruments EC820 Benchtop Conductivity Meter Kit
Кіраўніцтва карыстальніка
1. Уводзіны і агляд прадуктуview
The Apera Instruments EC820 Benchtop Conductivity Meter is a high-precision instrument designed for accurate measurement of Conductivity (EC), Total Dissolved Solids (TDS), Salinity, Resistivity, and temperature. This meter is equipped with advanced features for reliable and stable readings across a wide range of applications.
This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of your EC820 meter to ensure optimal performance and longevity.

Figure 1: Apera Instruments EC820 Benchtop Conductivity Meter Kit. The image shows the main meter unit, a flexible electrode arm and holder, and the conductivity electrode submerged in a beaker of liquid.
2. Тэхніка бяспекі
- Заўсёды асцярожна звяртайцеся з глюкометрам і электродамі, каб пазбегнуць пашкоджанняў.
- Do not immerse the main meter unit in water. The unit is IP54 water-resistant, but not submersible.
- Выкарыстоўвайце толькі адаптар сілкавання, які ўваходзіць у камплект.
- Keep calibration solutions and samples away from children and pets. Follow safety data sheets (SDS) for handling specific chemicals.
- Ensure the meter is placed on a stable, level surface during operation.
- Адключыце электрычнасць перад чысткай або тэхнічным абслугоўваннем.
3. Змесціва ўпакоўкі
Праверце, ці ёсць у вашай упакоўцы ўсе пералічаныя ніжэй прадметы:
- Дакладны настольны вымяральнік электраправоднасці EC820
- 2401T-F Platinum Glass-body Conductivity Electrode
- Flexible Electrode Arm and Holder
- Кабель USB
- PC-Link Software Flash Drive
- Power Adaptor (Input: 120V AC 60Hz; Output: 9V 300mA)
- Calibration Solutions:
- 84 µS/cm (1 vial)
- 1413 µS/cm (1 vial)
- 12.88 mS/cm (1 vial)

Figure 2: The 2401T-F Platinum Glass-body Conductivity Electrode, showing its connection cables.
4. Настройка
- Unpack the Meter: Акуратна дастаньце ўсе кампаненты з упакоўкі.
- Assemble Electrode Arm: Attach the flexible electrode arm to the meter unit. Ensure it is securely fastened.
- Connect Electrode: Plug the 2401T-F Conductivity Electrode into the designated "COND" port on the back of the meter. Ensure the connection is firm.

Figure 3: Rear panel of the EC820 meter, highlighting the "COND" and "TEMP" ports, along with RS232 and DC 9V power input.
- Падключыце харчаванне: Plug the power adapter into the "DC 9V" port on the back of the meter, then connect it to a standard 120V AC 60Hz power outlet.
- Першапачатковае ўключэнне: Press the power button to turn on the meter. The LCD display should illuminate.
5. Інструкцыя па эксплуатацыі
5.1. Каліброўка
The EC820 meter features 1 to 4 points auto-calibration. Regular calibration ensures accurate measurements.
- Prepare Solutions: Use the provided 84 µS/cm, 1413 µS/cm, and 12.88 mS/cm calibration solutions. Ensure solutions are at room temperature.
- Прамыўны электрод: Rinse the conductivity electrode thoroughly with distilled or deionized water before and after each measurement or calibration. Gently blot dry with a lint-free tissue.
- Увайдзіце ў рэжым каліброўкі: With the meter on, press the КАЛ button. The display will show "CAL" and prompt for the first calibration point.
- First Point Calibration: Immerse the electrode into the 1413 µS/cm standard solution. Wait for the reading to stabilize (indicated by a stable icon on the display). The meter will automatically recognize the solution. Press УВОД каб пацвердзіць.
- Subsequent Points (Optional): For higher accuracy, proceed with 84 µS/cm and 12.88 mS/cm solutions following the same procedure. The meter will guide you through the process.
- Exit Calibration: After completing desired calibration points, press the ВЫМЯР button to return to measurement mode.
Заўвага: The meter has a self-diagnosis function to help identify and fix common calibration problems. Refer to the on-screen prompts.
5.2. Вымярэнне
- Прамыўны электрод: Прамыйце электрод дыстыляванай вадой.
- Апускальны электрод: Апусціце электрод у sample solution, ensuring the sensor is fully submerged.
- Wait for Stability: Allow the reading to stabilize. The stable reading icon will appear on the LCD.
- Record Reading: Read the Conductivity (EC), TDS, Salinity, or Resistivity value displayed on the large LCD. Temperature will also be displayed simultaneously.
- Змяніць адзінкі: Націсніце АДЗІНКА button to cycle through different measurement units (e.g., µS/cm, mS/cm, ppm, ppt).
- Захоўванне дадзеных: The meter supports GLP data management with 500 groups of data storage. Use the M+ / R-M buttons to store and recall data.
- Экспарт дадзеных: Connect the meter to a PC via the USB cable and use the provided PC-Link software (Windows-based system only) to export data.
6. Тэхнічнае абслугоўванне
- Ачыстка электродаў:
- Regularly rinse the electrode with distilled or deionized water.
- For stubborn deposits, refer to the electrode's specific cleaning instructions. Generally, a mild detergent solution or a specific electrode cleaning solution can be used, followed by thorough rinsing.
- Do not scratch or damage the platinum black sensor.
- Захоўванне электродаў:
- Always store the conductivity electrode in its protective cap filled with a proper electrode storage solution (e.g., 3M KCl solution or Apera Instruments storage solution). Never store dry.
- Meter Cleaning: Wipe the main meter unit with a clean, damp тканіна. Не выкарыстоўвайце абразіўныя ачышчальнікі або растваральнікі.
- Абнаўленні праграмнага забеспячэння: Check the Apera Instruments website periodically for any software updates for the PC-Link software.

Малюнак 4: Буйны план view of the platinum glass-body conductivity electrode tip, which requires careful handling and proper storage.
7. Выпраўленне непаладак
| праблема | Магчымая прычына | Рашэнне |
|---|---|---|
| Лічыльнік не ўключаецца | Няма блока харчавання; няспраўны адаптар; дрэннае злучэнне. | Check power adapter connection and outlet. Ensure adapter is functional. |
| Няўстойлівыя паказанні | Dirty electrode; air bubbles on sensor; incorrect calibration; temperature fluctuations. | Clean electrode; gently tap electrode to remove bubbles; recalibrate meter; ensure sample temperature is stable. |
| Памылка каліброўкі | Contaminated calibration solution; incorrect solution used; damaged electrode. | Use fresh calibration solutions; ensure correct solution for calibration point; inspect electrode for damage. |
| No data transfer to PC | Incorrect USB connection; software not installed or running; driver issues. | Verify USB cable connection; ensure PC-Link software is installed and open; check device manager for driver issues. |
8. Тэхнічныя характарыстыкі
| Параметр | Каштоўнасць |
|---|---|
| Нумар мадэлі | АІ532 |
| Параметры вымярэння | Conductivity (EC), TDS, Salinity, Resistivity, Temperature |
| Дыяпазон праводнасці | 0 to 2,000 mS |
| Дакладнасць | ±0.5% FS |
| Кропкі каліброўкі | 1 to 4 points auto-calibration (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm) |
| Тэмпературная кампенсацыя | Аўтаматычная кампенсацыя тэмпературы (ATC) |
| Захоўванне дадзеных | 500 groups (GLP compliant) |
| Сувязь | USB for PC data export |
| Тып дысплея | Вялікі ВК з падсветкай |
| Электразабеспячэнне | 9V DC, 300mA (120V AC 60Hz adapter included) |
| Абарона ад пранікнення | Воданепранікальнасць IP54 |
| Сертыфікаты | CE, RoHS, ISO 9001:2015 |
| Памеры ўпакоўкі | 10.63 х 9.88 х 6.61 цалі |
| Вага | 6.5 фунта |
9. Гарантыя і падтрымка
Apera Instruments products are manufactured under an ISO 9001:2015 certified quality system, ensuring high standards of quality and reliability. For specific warranty information and technical support, please refer to the warranty card included with your product or visit the official Apera Instruments webсайт.
For assistance with troubleshooting, calibration, or general inquiries, please contact Apera Instruments customer service. Contact details can typically be found on their official webсайце або ва ўпакоўцы прадукту.
Інтэрнэт-рэсурсы: Apera Instruments Store on Amazon