POOLEX PC-SLP150

Кіраўніцтва карыстальніка цеплавога помпы для басейна POOLEX PC-SLP150 Silverline 150

Марка: ПУЛЕКС

мадэль: PC-SLP150 Silverline 150

1. Уводзіны і большview

This manual provides comprehensive instructions for the installation, operation, and maintenance of the POOLEX PC-SLP150 Silverline 150 Pool Heat Pump. Designed for pools up to 75 m3, this heat pump features a high-performance Mitsubishi compressor and a titanium exchanger for efficient and silent pool heating.

Асноўныя функцыі ўключаюць у сябе:

  • High-performance Mitsubishi compressor.
  • Double-spiral titanium exchanger and twisted tech titanium coil for rapid heating.
  • Durable metallic casing with anti-UV and anti-corrosion properties.
  • Automatic thermostatic control.
  • Compatibility with salt treatment systems.
  • User-friendly LCD control panel with Touch & Go technology (optional Wi-Fi module available).
POOLEX PC-SLP150 Silverline 150 Pool Heat Pump

Image 1: POOLEX PC-SLP150 Silverline 150 Pool Heat Pump. This image shows the compact, grey-colored heat pump unit with a circular fan grille on the side and the "POOLEX Silverline" logo prominently displayed.

2. Інфармацыя па бяспецы

Please read all safety instructions carefully before installing, operating, or performing maintenance on the heat pump. Failure to follow these instructions may result in property damage, serious injury, or death.

  • Электрабяспека: Ensure the unit is properly grounded. All electrical connections must be performed by a qualified electrician in accordance with local and national electrical codes. Disconnect power before any service or maintenance.
  • Бяспека вады: Do not operate the heat pump if there is a risk of freezing water inside the unit. Ensure proper water flow through the unit.
  • Ўстаноўка: Install the unit on a stable, level surface. Maintain adequate clearance around the unit for proper airflow and ventilation. Keep children and pets away from the unit during operation.
  • Тэхнічнае абслугоўванне: Only use manufacturer-approved replacement parts. Do not attempt to modify the unit.
  • Хімічныя рэчывы: Avoid direct contact of pool chemicals with the heat pump casing.

3. Змесціва ўпакоўкі

Before proceeding with installation, please verify that all the following components are included in your package:

  • POOLEX PC-SLP150 Silverline 150 Heat Pump Unit
  • Anti-vibration support kit
  • PVC connectors Ø 50mm 1½''
  • Шланг для адводу кандэнсату
  • Камплект для абслугоўвання
  • Wired control extension (10m)
  • Multi-language user manual (this document)

4. Настройка і ўстаноўка

Proper installation is crucial for the efficient and safe operation of your heat pump. It is highly recommended that installation be performed by a qualified professional.

4.1. размяшчэнне

  • Choose a location with good airflow, away from walls or other obstructions.
  • Ensure the unit is placed on a solid, level surface capable of supporting its weight (54 kg).
  • Install the anti-vibration supports to minimize operational noise and vibration.
  • Position the unit to allow for easy access for maintenance.

4.2. Сантэхнічныя злучэнні

  • Connect the heat pump to your pool's filtration system using the provided PVC connectors (Ø 50mm 1½'').
  • Пераканайцеся, што ўсе злучэнні герметычныя, каб пазбегнуць уцечак.
  • Install the condensate drain hose to direct condensed water away from the unit's base.

4.3. Электрычныя злучэнні

  • All electrical wiring must comply with local regulations and be carried out by a certified electrician.
  • Пераканайцеся, што крыніца харчавання адпавядае характарыстыкам цеплавога помпы.
  • Connect the wired control extension (10m) if remote control panel placement is desired.

4.4. Першапачатковы запуск

  • Before powering on, ensure the pool pump is running and water is flowing through the heat pump.
  • Turn on the electrical supply to the heat pump.
  • Follow the operating instructions to set your desired pool temperature.

5. Інструкцыя па эксплуатацыі

The POOLEX PC-SLP150 Silverline 150 is designed for user-friendly operation via its LCD control panel.

5.1. Уключэнне / выключэнне харчавання

  • To power on, ensure the main power supply is connected and press the power button on the LCD control panel.
  • Каб выключыць, націсніце кнопку харчавання яшчэ раз.

5.2. Устаноўка тэмпературы

  • Use the "Touch & Go" interface on the LCD panel to navigate menus.
  • Select the temperature setting option and adjust to your desired pool water temperature.
  • The unit will automatically begin heating until the set temperature is reached.

5.3. Рэжымы працы

The heat pump primarily operates in heating mode. It will automatically regulate its operation to maintain the set temperature efficiently.

5.4. Wi-Fi Module (Optional)

An optional Wi-Fi module can be integrated for remote control and monitoring. Refer to the separate instructions provided with the Wi-Fi module for setup and operation.

6. Тэхнічнае абслугоўванне

Regular maintenance ensures the longevity and optimal performance of your POOLEX heat pump.

6.1. Рэгулярная ўборка

  • Keep the exterior of the unit clean, wiping it with a soft, damp тканіна.
  • Ensure the air intake and outlet grilles are free from leaves, debris, and other obstructions. Blocked airflow can reduce efficiency.

6.2. Адвод кандэнсату

  • Periodically check the condensate drain hose to ensure it is not blocked and water can flow freely.

6.3. Падрыхтоўка да зімы

Before the winter season or when temperatures are expected to drop below freezing, perform the following steps:

  • Turn off the heat pump and disconnect its electrical supply.
  • Drain all water from the heat pump and associated plumbing to prevent freezing damage.
  • Cover the unit with a protective, breathable cover designed for outdoor appliances.

6.4. Maintenance Kit

Utilize the included maintenance kit for any specific cleaning or care instructions provided by POOLEX.

7. Выпраўленне непаладак

This section addresses common issues you might encounter. For problems not listed here or if solutions do not resolve the issue, contact qualified service personnel.

праблемаМагчымая прычынаРашэнне
Heat pump does not turn on.No power supply; circuit breaker tripped; unit switch off.Check power connections; reset circuit breaker; ensure unit is switched on at the control panel.
Pool water is not heating.Incorrect temperature setting; insufficient water flow; air blockage; low ambient temperature.Verify temperature setting; ensure pool pump is running and filters are clean; check for obstructions around the unit; heat pump efficiency decreases in very cold weather.
Незвычайны шум падчас працы.Loose components; fan obstruction; unit not level; anti-vibration supports not installed correctly.Inspect for loose parts; clear any fan obstructions; ensure unit is on a level surface; verify anti-vibration supports are properly installed. If noise persists, contact service.
Error code on LCD display.Унутраная памылка; праблема з датчыкам.Note the error code and consult the full technical manual or contact customer support.

8. Тэхнічныя характарыстыкі

Нумар мадэліПК-SLP150
МаркаПУЛЕКС
Памеры (Д х Ш х У)92.7 х 34 х 63.6 см
Вага54 кг
Награвальная магутнасць15 кВт
Рэкамендаваны аб'ём басейнаДа 75 м3
Тып кампрэсараMitsubishi High-Performance
ЦеплаабменнікDouble-spiral titanium, Twisted Tech titanium coil
КС (умовы 26/26)> 6
Панэль кіраванняLCD з тэхналогіяй Touch & Go
CasinМатэрыялMetallic, anti-UV, anti-corrosion

9. Гарантыя і падтрымка

POOLEX is committed to customer satisfaction. For detailed warranty information, technical assistance, or to inquire about replacement parts, please refer to the official POOLEX webсайт або звярніцеся да аўтарызаванага прадаўца.

You can often find additional support resources, FAQs, and contact information on the manufacturer's webсайт.

© 2025 POOLEX. Усе правы абаронены.