TRACEABLE B07R5N7QYS

Адсочваемы калібраваны тэрмагігрометр з інструкцыяй па эксплуатацыі RS-232

Model: B07R5N7QYS

1. Уводзіны

This manual provides detailed instructions for the proper use and maintenance of your Traceable Calibrated Thermohygrometer with RS-232. This device is designed for accurate measurement of temperature and humidity, featuring microprocessor-based technology for easy calibration and an RS-232 output for data communication. For optimal performance and longevity, please read these instructions thoroughly before operation.

Traceable Calibrated Thermohygrometer device

Image 1: The Traceable Calibrated Thermohygrometer. The device features a digital display showing humidity and temperature, with several control buttons below. A probe is connected via a coiled cable.

2. Асаблівасці

  • Accurately measures temperature and relative humidity.
  • Includes a NIST-Traceable certificate from an A2LA accredited calibration laboratory (1750.01), ensuring measurement accuracy.
  • Microprocessor-based design facilitates quick and straightforward calibration procedures.
  • Equipped with RS-232 output for data transmission to compatible systems.

3. Што ў скрынцы

Upon unpacking, verify that the following items are present:

  • Traceable Calibrated Thermohygrometer unit
  • Humidity/Temperature Probe
  • NIST-Traceable Calibration Certificate
  • Кіраўніцтва па эксплуатацыі

4. Настройка

  1. Ўстаноўка батарэі: Open the battery compartment (typically on the back of the unit) and insert the required batteries, observing correct polarity.
  2. Злучэнне зонда: Connect the humidity/temperature probe to the designated port on the main unit. Ensure a secure connection.
  3. Першапачатковае ўключэнне: Націсніце ON button to power on the device. The display should illuminate and show initial readings.
  4. Unit Selection (if applicable): If your model allows, select your preferred temperature unit (Celsius or Fahrenheit) using the ° C / ° F кнопка.
  5. Размяшчэнне: Position the thermohygrometer in the environment where measurements are required. Ensure the probe is exposed to the air and not obstructed.

5. Інструкцыя па эксплуатацыі

5.1 Асноўныя аперацыі

  • Уключэнне/выключэнне харчавання: Націсніце ON button to turn the unit on. Press the ВЫКЛ кнопку, каб выключыць яго.
  • Дысплей для чытання: The display will show current relative humidity (RH%) and temperature (°C/°F).
  • Адзінка вымярэння тэмпературы: Toggle between Celsius (°C) and Fahrenheit (°F) by pressing the ° C / ° F кнопка.
  • Утрыманне дадзеных: Націсніце ТРЫМАЦЬ button to freeze the current readings on the display. Press again to release.
  • Minimum/Maximum Readings: Націсніце MIN / MAX кнопка для view the minimum and maximum temperature and humidity readings recorded since the last reset. Press repeatedly to cycle through MIN, MAX, and current readings.
  • Reset MIN/MAX: Пакуль viewing MIN/MAX readings, press the СКІД button to clear the stored minimum and maximum values.

5.2 RS-232 Output

The device is equipped with an RS-232 port for connecting to a computer or data logger. This allows for real-time data acquisition and analysis. Refer to the specific software or interface instructions for your data collection system for details on establishing communication and data transfer protocols.

Hand interacting with a Traceable device

Image 2: A hand in a blue glove interacting with a Traceable device, demonstrating typical laboratory use. This image illustrates the practical application of Traceable instruments in a controlled environment.

6. Тэхнічнае абслугоўванне

  • Уборка: Wipe the unit and probe with a soft, damp тканіна. Не выкарыстоўвайце абразіўныя ачышчальнікі або растваральнікі.
  • Замена батарэі: Replace batteries when the low battery indicator appears on the display. Ensure proper battery type and polarity.
  • захоўванне: When not in use for extended periods, remove the batteries and store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Перакаліброўка: Due to the nature of humidity sensors, periodic recalibration is recommended to maintain accuracy. Refer to the NIST-Traceable certificate for recommended recalibration intervals.

7. Выпраўленне непаладак

праблемаМагчымая прычынаРашэнне
Няма дысплея або дысплей цьмяныРазраджаныя або слабыя батарэі; няправільная ўстаноўка батарэй.Заменіце батарэйкі новымі, выконваючы палярнасць.
Няправільныя паказанніSensor contamination; need for recalibration; probe not properly connected.Clean the probe gently; perform recalibration; ensure probe is securely connected.
RS-232 communication failureIncorrect cable; software settings mismatch; port issue.Verify cable connection and type; check software communication settings (baud rate, parity); try a different USB/serial port.

8. Тэхнічныя характарыстыкі

ПараметрКаштоўнасць
Нумар мадэліB07R5N7QYS
ВытворцаКОЎЛ-ПАРМЕР
КаліброўкаNIST-Traceable (A2LA accredited 1750.01)
ІнтэрфейсРС-232
Дата першай даступнасці29 красавіка 2019 г

9. Гарантыя і падтрымка

For warranty information and technical support, please contact the manufacturer, Cole-Parmer, or your authorized distributor. Keep your purchase receipt and NIST-Traceable certificate for reference.

вытворца: КОЎЛ-ПАРМЕР

Марка: ПРАСЛЕДЧЫМ

Для атрымання дадатковай дапамогі наведайце Traceable Brand Store on Amazon.