Extreme Networks Summit X460-24p

Extreme Networks Summit X460-24p Managed Switch User Manual

Model: X460-24p (Part Number: 16403)

Уводзіны

This manual provides instructions for the Extreme Networks Summit X460-24p, a high-performance, managed Layer 3 Ethernet switch designed for enterprise and data center environments. It features 24 Gigabit Ethernet ports with Power over Ethernet (PoE) capabilities, along with additional SFP and shared Gigabit SFP ports for flexible connectivity.

Інфармацыя па бяспецы

Інструкцыі па бяспецы

  • Always disconnect all power supply inputs before removing any panel for servicing.
  • This device contains a Class 1 Laser product. Avoid direct eye exposure to beam.
  • Забяспечце належнае зазямленне падчас мантажу.
  • Refer to the installation manual for power cord selection and additional compliance markings.

Змест пакета

Што ў скрынцы

  • Extreme Networks Summit X460-24p Switch
  • Шнур харчавання (залежна ад рэгіёна)
  • Камплект для мантажу ў стойку
  • Дакументацыя (гэтае кіраўніцтва)

Прадукт скончаныview

The Summit X460-24p switch is designed for efficient network management and high-speed data transfer.

Задняя панэль

Тыл view of the Extreme Networks Summit X460-24p switch, showing power input, fan modules, and SummitStack ports.

This image displays the rear panel of the Summit X460-24p switch, highlighting the power input, fan modules, and the SummitStack ports. The overall chassis is purple.

Close-up of the SummitStack ports on the rear panel of the switch, labeled 'Stack Port 1' and 'Stack Port 2'.

Падрабязны view of the SummitStack ports (Stack Port 1 and Stack Port 2) located on the rear of the switch, used for stacking multiple switches.

Этыкетка прадукту

Close-up of the product label on the Extreme Networks Summit X460-24p switch, showing Model 16403, Summit X460-24p, System No. 800323-00-03, and Serial No. 1052G-03941.

This label provides critical identification information for the switch, including Model: 16403, Summit X460-24p, System No.: 800323-00-03, and Serial No.: 1052G-03941.

Дадатковыя кампаненты

Label for an Extreme Networks Summit 750W PoE AC PSU, showing Model 10931, System No. 800382-00-03, and Serial No. 1053A-41986.

This image shows the label for an optional Extreme Networks Summit 750W PoE AC Power Supply Unit (PSU), Model 10931, System No. 800382-00-03, Serial No. 1053A-41986.

Label for an Extreme Networks SummitStack Module, showing Model 16419, System No. 800384-00-01, and Serial No. 1122G-02565.

This image displays the label for an optional Extreme Networks SummitStack Module, Model 16419, System No. 800384-00-01, Serial No. 1122G-02565.

Настройка

Кіраўніцтва па ўстаноўцы

Мацаванне стойкі

The Summit X460-24p is designed for standard 19-inch rack mounting. Use the provided rack-mounting kit to secure the switch in a server rack. Ensure adequate ventilation around the unit.

Падключэнне харчавання

Connect the power cord to the AC power inlet on the rear of the switch and then to a grounded electrical outlet. The switch will power on automatically.

Падключэнне сеткавых кабеляў

  • Connect Ethernet cables from your network devices to the 24 10/100/1000Base-T PoE ports on the front panel.
  • For uplink or fiber connections, use the SFP or shared Gigabit SFP ports.
  • For stacking, connect SummitStack ports on multiple switches using appropriate stacking cables.

Initial Configuration Access

Access the switch's management interface via a console cable connected to the console port, or through a web browser if the switch has a default IP address configured. Refer to the Extreme Networks documentation for detailed initial setup procedures.

Інструкцыя па эксплуатацыі

Базавая аперацыя

Уключэнне/выключэнне харчавання

The switch powers on automatically when connected to a power source. To power off, disconnect the power cord. For proper shutdown, it is recommended to use the software-based shutdown command if available.

Святлодыёдныя індыкатары

Observe the LED indicators on the front panel for status information regarding power, system health, port activity, and PoE status. Consult the full product documentation for a detailed explanation of each LED's behavior.

Інтэрфейс кіравання

The switch can be managed via a Command Line Interface (CLI) accessible through the console port or Telnet/SSH, or through a web-based graphical user interface (GUI).

Тэхнічнае абслугоўванне

Догляд і абслугоўванне

Уборка

Keep the switch clean and free of dust. Use a soft, dry cloth for external cleaning. Do not use liquid or aerosol cleaners.

Абнаўленне прашыўкі

Periodically check the Extreme Networks support website for firmware updates to ensure optimal performance and security. Follow the provided instructions for firmware upgrade procedures.

Модулі вентылятараў і блокаў харчавання

The switch may feature hot-swappable fan and power supply modules. Refer to the Extreme Networks documentation for instructions on replacement if necessary.

Ліквідацыю непаладак

Агульныя праблемы

Няма сілы

  • Пераканайцеся, што шнур харчавання надзейна падключаны як да выключальніка, так і да разеткі.
  • Пераканайцеся, што разетка працуе.

Port Link Down

  • Праверце падключэнне кабеля Ethernet з абодвух канцоў.
  • Праверце, ці падключаная прылада ўключана і ці працуе яна правільна.
  • Check the port status via the management interface.

Праблемы з падключэннем да сеткі

  • Verify IP configuration and network settings.
  • Check for conflicting IP addresses.
  • Consult network diagnostics tools.

Тэхнічныя характарыстыкі

Тэхнічныя характарыстыкі

АсаблівасцьАпісанне
мадэльSummit X460-24p (Part Number: 16403)
Парты24 x 10/100/1000Base-T PoE+ ports, 4 x shared Gigabit SFP, 4 x SFP
ПластКіраваны камутатар 3-га ўзроўню
МаркаЭкстрэмальныя сеткі
Тып інтэрфейсуPoE, SFP
Сістэмны нумар800323-00-03
Серыйны нумар1052G-03941
UPC683332278646

Гарантыя і падтрымка

Інфармацыя аб гарантыі

This product typically comes with a 90-day limited warranty. For specific warranty terms and conditions, please refer to the official Extreme Networks warranty statement or contact your vendor.

Тэхнічная падтрымка

For technical assistance, visit the official Extreme Networks support webсайт або звярніцеся ў службу падтрымкі кліентаў. Падрыхтуйце мадэль і серыйны нумар вашага прадукту, калі будзеце звяртацца па падтрымку.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.