Першая трывога 1044807

First Alert Z-Wave Smoke & Carbon Monoxide Alarm

Мадэль: 1044807

Кіраўніцтва карыстальніка

1. Уводзіны

The First Alert Z-Wave Smoke & Carbon Monoxide Detector Alarm is a wireless, battery-powered device designed to enhance home safety by detecting both smoke and carbon monoxide. It offers improved compatibility with the Ring Alarm Security System and other certified Z-Wave systems, providing mobile alerts in emergency situations. This 2-in-1 alarm features a photoelectric smoke-sensing chamber, an electrochemical carbon monoxide sensor, an 85-decibel horn, a tamper-resistant battery door, and a single test/silence button. It is suitable for residential and institutional applications, including sleeping areas in hospitals, hotels, dorms, and multi-family dwellings, complying with various safety standards such as UL217, UL2034, and NFPA 101.

2. Інфармацыя па бяспецы

Please read and understand all instructions before installing and operating this alarm. Failure to do so may result in property damage, injury, or death. This alarm is designed to detect smoke and carbon monoxide. It is not designed to detect fire, heat, or other gases. For optimal performance, ensure the alarm is installed according to these instructions and regularly maintained.

  • Важна: Do not paint the alarm. Paint can clog the sensing chambers and prevent the alarm from operating properly.
  • Бяспека акумулятара: Use only the specified batteries. Do not mix old and new batteries, or different types of batteries. Dispose of used batteries properly.
  • Адпаведнасць: This alarm complies with UL217, UL2034, CSFM, NFPA 720, NFPA 101, and other relevant standards.

3. Змесціва ўпакоўкі

Праверце, ці ёсць усе прадметы ў вашай упакоўцы:

  • First Alert Z-Wave Smoke & Carbon Monoxide Alarm Unit
  • 2 батарэйкі АА (уключаны)
  • Мантажны кранштэйн
  • Мантажныя шрубы і анкеры

4. Настройка

4.1 Устаноўка батарэі

The alarm requires two AA batteries for operation. Do not insert the batteries until prompted by your Z-Wave hub's setup process, especially if integrating with a Ring Alarm system.

First Alert Z-Wave Smoke and CO Alarm with open battery compartment showing two AA batteries.

Image: The alarm unit with its battery compartment open, revealing two AA batteries. The battery compartment is designed for easy access.

  1. Locate the battery compartment on the side of the alarm unit.
  2. Адкрыйце дзверцы батарэі.
  3. Устаўце дзве батарэйкі тыпу АА, сачыце за правільнай палярнасцю (+/-).
  4. Close the battery door securely. The alarm may chirp or beep to indicate it is powered on.

4.2 Месца мацавання

Proper placement of the alarm is crucial for effective detection. Install the alarm in all sleeping areas and on every level of your home, including the basement. For carbon monoxide detection, consider placing an alarm near potential sources of CO, such as attached garages or areas with fuel-burning appliances.

Diagram showing recommended placement of smoke and carbon monoxide alarms and fire extinguishers in a multi-level house.

Image: A visual guide illustrating recommended locations for smoke and CO alarms (represented by icons) throughout different rooms and levels of a house, including bedrooms, living room, kitchen, hallway, basement, and garage.

  1. Choose a location on a wall or ceiling, away from direct sunlight, vents, or areas with high humidity.
  2. Выкарыстоўвайце прадастаўлены мантажны кранштэйн у якасці шаблону для разметкі адтулін.
  3. Прасвідруйце адтуліны і пры неабходнасці ўстаўце анкеры.
  4. Secure the mounting bracket to the wall or ceiling with screws.
  5. Attach the alarm unit to the mounting bracket by twisting it clockwise until it locks into place.

4.3 Z-Wave Pairing (Smart Start)

This alarm features Z-Wave Plus with Smart Start, allowing for faster and more intuitive connection to your compatible Z-Wave gateway hub. Ensure your hub supports this First Alert detector.

First Alert Z-Wave Smoke and CO Alarm with Z-Wave Plus and Works with Ring logos.

Image: The First Alert Z-Wave Smoke and CO Alarm unit, prominently displaying the Z-Wave Plus logo and a "Works with Ring" logo, indicating its compatibility with Z-Wave networks and Ring Alarm systems.

  1. Open your Z-Wave gateway hub's mobile application or interface.
  2. Initiate the "Add Device" or "Pair Device" process within your hub's settings.
  3. Locate the QR code on the back of your First Alert alarm unit.
  4. Use your hub's app to scan the QR code. The Smart Start feature will automatically begin the pairing process.
  5. Follow any on-screen prompts from your hub's application to complete the setup.
  6. Once successfully paired, you should receive real-time notifications in your app when smoke or carbon monoxide is detected.

5. Аперацыйная

5.1 Кнопка "Праверка/цішыня".

The large button on the front of the alarm serves as both the Test and Silence button.

Фронт view of the First Alert Z-Wave Smoke and CO Alarm, showing the test/silence button and indicator lights.

Выява: Ясна view of the front of the First Alert Z-Wave Smoke and CO Alarm, highlighting the central "TEST/SILENCE" button and the indicator lights for CO, Smoke, and Power.

  • Каб праверыць: Press and hold the Test/Silence button for a few seconds. The alarm will sound a test pattern (e.g., 3 beeps for smoke, 4 beeps for CO). This confirms the alarm's electronics, battery, and horn are working.
  • To Silence: In the event of a nuisance alarm (e.g., from cooking smoke), press the Test/Silence button to temporarily silence the alarm. The alarm will automatically reset after a few minutes if the smoke or CO concentration has cleared.

5.2 Светавыя індыкатары

The alarm features several indicator lights to communicate its status:

  • Харчаванне (зялёны святлодыёд): Flashes approximately once per minute to indicate normal operation.
  • Smoke (Red LED): Flashes rapidly during a smoke alarm.
  • CO (Red LED): Flashes rapidly during a carbon monoxide alarm.
  • Trouble/Malfunction (Yellow LED): Indicates a fault or low battery. Refer to the troubleshooting section.

6. Тэхнічнае абслугоўванне

6.1 Рэгулярнае тэсціраванне

Test your alarm weekly by pressing the Test/Silence button. This ensures the alarm is functioning correctly.

6.2 Замена батарэі

The alarm will chirp periodically (e.g., once every minute) and the yellow LED will flash to indicate a low battery. Replace both AA batteries immediately when this occurs. Refer to Section 4.1 for battery installation steps.

6.3 Ачыстка

Clean your alarm at least once a month to remove dust and debris. Use a soft brush attachment on your vacuum cleaner to gently vacuum the alarm's cover and vents. Do not use cleaning solvents or sprays directly on the alarm.

7. Выпраўленне непаладак

праблемаМагчымая прычынаРашэнне
Alarm chirps once every minute.Нізкі акумулятар.Заменіце абедзве батарэйкі тыпу АА.
Alarm sounds intermittently or false alarms.Dust or debris in sensing chamber; high humidity; cooking fumes.Clean the alarm (Section 6.3). Move alarm away from high humidity areas or cooking sources. Press silence button for temporary silence.
Alarm does not respond to test button.No power; dead batteries; unit malfunction.Ensure batteries are correctly installed and charged. Replace batteries. If issue persists, replace the unit.
Alarm does not pair with Z-Wave hub.Hub incompatibility; incorrect pairing procedure; distance from hub.Consult your Z-Wave hub's manual for compatibility. Ensure correct Smart Start procedure. Move alarm closer to the hub.

8. Тэхнічныя характарыстыкі

АсаблівасцьДэталь
МаркаПершая абвестка
Нумар мадэлі1044807
стыльСтандартнае выяўленне
Крыніца харчаванняПрацуе ад батарэек (2 батарэйкі тыпу АА ў камплекце)
КолерБелы
Памеры прадукту2" Г x 5" Ш x 5" У
Вага прадмета10.88 унцыі
Тып сігналізацыіAudible (85-decibel horn)
Працоўная вільготнасць10% да 95% адноснай вільготнасці (RH)
Працоўная тэмпература40°F (4°C) да 100°F (38°C)
Тып датчыкаФотаэлектрычны (дым), электрахімічны (CO)
МатэрыялПластыкавыя
UPC029054021694

9. Гарантыя і падтрымка

This First Alert Z-Wave Smoke & Carbon Monoxide Alarm comes with a 7-гадовая абмежаваная гарантыя. For detailed warranty information or technical support, please refer to the official First Alert website or contact their customer service. Ensure you retain your proof of purchase for warranty claims.

Ask a question about this manual