DANOPLUS KIB-006

DANOPLUS K Type Thermometer Data Logger

Model: KIB-006 - Instruction Manual

1. Уводзіны

The DANOPLUS KIB-006 is a 4-channel K-type thermocouple thermometer data logger designed for precise temperature measurement and recording. This device allows for simultaneous monitoring of up to four temperature points, storing data directly onto an SD card for easy retrieval and analysis without requiring specialized software. It features a large LCD with backlight for clear readings, programmable high/low limit alarms, and various measurement functions suitable for a wide range of industrial, laboratory, and environmental applications.

DANOPLUS KIB-006 4-channel K-type thermometer data logger with four yellow thermocouple probes connected, displaying temperature readings on its screen.

Image: The DANOPLUS KIB-006 thermometer with four K-type thermocouple probes connected, showing its digital display and an 8GB SD card.

2. Змесціва ўпакоўкі

Калі ласка, праверце змесціва пасылкі пасля атрымання, каб пераканацца ў наяўнасці ўсіх прадметаў і іх цэласнасці:

  • 1 x DANOPLUS KIB-006 4-Channel K-Type Thermometer SD Logger
  • 2 x K-Type Thermocouple Probes
  • 1 х 8 ГБ SD-карта
  • 4 батарэек тыпу АА
  • 1 x English Operation Manual (this document)
  • Standard Factory Packaging
Contents of the DANOPLUS KIB-006 package, including the thermometer, two K-type thermocouples, an 8GB SD card, and batteries.

Image: The DANOPLUS KIB-006 thermometer, two K-type thermocouples, an 8GB SD card, and batteries, representing the included items.

3. Асноўныя магчымасці

  • 4-Channel Measurement: Simultaneously displays temperature readings from up to four K-type thermocouple probes.
  • SD Card Data Logging: Records unlimited temperature data directly to an included 8GB SD card in TXT format, eliminating the need for software.
  • Programmable High/Low Limit Alarm: Features an audible buzzer and LED indicator that activate when temperature thresholds are exceeded.
  • Шырокі дыяпазон вымярэнняў: Capable of measuring temperatures from -200 to 1370°C (-328 to 2498°F) for the main unit.
  • Large LCD with Backlight: Provides clear temperature readings and operational status, with an adjustable backlight for low-light conditions.
  • MAX/MIN/HOLD Function: Дазваляе карыстальнікам view maximum, minimum, and hold current measured values on the screen.
  • Switchable Units: Easily switch between Celsius (°C) and Fahrenheit (°F).
  • Differential Temperature (T1-T2): Calculates and displays the temperature difference between two selected channels.
  • Аўтаматычнае выключэнне: Conserves battery life by automatically shutting down after 20 minutes of inactivity.
Diagram showing the key features of the DANOPLUS KIB-006 thermometer, including 4 channels, SD card datalogger, wide measurement range, Hi/Low temperature alarm, switchable temperature unit, and data hold function.

Image: Visual representation of the thermometer's features, including its 4-channel capability, SD card data logging, wide measurement range, alarm, unit switching, and data hold.

4. Кіраўніцтва па наладцы

4.1. Устаноўка батарэі

  1. Знайдзіце вечка батарэйнага адсека на задняй панэлі прылады.
  2. Адкрыйце крышку.
  3. Устаўце 4 батарэйкі АА, выконваючы палярнасць (+/-).
  4. Надзейна зачыніце крышку батарэйнага адсека.

4.2. Устаўка SD-карты

  1. Знайдзіце слот для SD-карты на бакавой панэлі прылады.
  2. Gently insert the provided 8GB SD card into the slot until it clicks into place. Ensure the card is oriented correctly.
  3. Каб выняць, націсніце на SD-карту ўнутр, пакуль яна не выскочыць.
Буйны план view of the DANOPLUS KIB-006 showing the SD card slot and how to insert an SD card.

Image: Demonstrates the insertion of an SD card into the data logger for data storage.

4.3. Падключэнне тэрмапары

  1. Identify the four K-type thermocouple input ports on the top of the device, labeled CH1, CH2, CH3, and CH4.
  2. Connect the K-type thermocouple probes to the desired channels. Ensure the positive (+) and negative (-) terminals of the probe match the corresponding markings on the device's input ports.
  3. Gently push the probe connectors firmly into the ports until they are secure.
Буйны план view of the DANOPLUS KIB-006's four K-type thermocouple input ports, showing a yellow probe being inserted into one of the channels.

Image: Illustrates the connection of a K-type thermocouple probe into one of the four input channels on the device.

5. Аперацыя

5.1. Уключэнне/выключэнне харчавання

  • Націсніце ВКЛ/ВЫКЛ кнопку для ўключэння прылады.
  • Каб выключыць харчаванне, націсніце і ўтрымлівайце ВКЛ/ВЫКЛ кнопку прыблізна на 3 секунды.

5.2. Кіраванне падсветкай

  • Націсніце ВКЛ/ВЫКЛ button briefly to toggle the LCD backlight on or off.

5.3. Вымярэнне тэмпературы

  • Once powered on and thermocouples are connected, the device will immediately begin displaying real-time temperature readings for each active channel.

5.4. MAX/MIN/HOLD Function

Гэтая функцыя дазваляе вам view the maximum, minimum, and current held values during a measurement session.

  1. Націсніце МАКС/МІН/ФІК button once to display the maximum (MAX) temperature recorded.
  2. Націсніце МАКС/МІН/ФІК button again to display the minimum (MIN) temperature recorded.
  3. Націсніце МАКС/МІН/ФІК button a third time to hold the current readings (HOLD).
  4. Націсніце МАКС/МІН/ФІК button a fourth time to return to real-time measurement mode.
Video demonstrating the MAX/MIN/HOLD function of the DANOPLUS KIB-006 thermometer. It shows how to cycle through maximum, minimum, and hold values on the display.

Video: Demonstration of the MAX/MIN/HOLD function on the DANOPLUS KIB-006 thermometer.

5.5. Data Logging to SD Card

The device records temperature data to the SD card in a simple TXT file format, which can be opened with any text editor or spreadsheet software.

  • Каб пачаць запіс, націсніце ЗАПІС button. The 'REC' indicator will appear on the screen.
  • Каб спыніць запіс, націсніце ЗАПІС button again. The 'REC' indicator will disappear.
  • У ыampling rate for data logging can be programmed (refer to advanced settings in the full manual for details).

5.6. Alarm Function (High/Low Limit)

The thermometer features programmable high and low temperature alarms.

  • When a measured temperature exceeds the set high limit or falls below the set low limit, the device will activate an audible buzzer and an LED indicator.
  • Refer to the full manual for instructions on how to set specific high and low alarm thresholds.
DANOPLUS KIB-006 thermometer displaying temperature readings with an alarm icon and sound waves indicating the beeper/LED alarm function.

Image: The thermometer indicating an active alarm with visual and auditory cues.

5.7. Unit Switching (°C/°F)

  • Націсніце ° C / ° F button (often combined with another function button, refer to button labels) to toggle between Celsius and Fahrenheit temperature units.

5.8. Differential Temperature (T1-T2)

  • Націсніце Т1-Т2 button to display the temperature difference between channel 1 and channel 2.

6. Дадаткі

The DANOPLUS KIB-006 is suitable for a variety of temperature monitoring tasks, including but not limited to:

  • Сістэмы HVAC: Monitoring air conditioning and heating system performance.
  • Прамысловыя працэсы: Temperature control in manufacturing, machinery, and equipment.
  • Лабараторнае выкарыстанне: Research, experiments, and quality control requiring precise temperature data.
  • Food Service: Monitoring temperatures in ovens, refrigerators, and freezers.
  • акварыумы: Maintaining stable water temperatures for aquatic life.
  • Refrigeration Equipment: Performance testing and maintenance of cooling units.
Grid of images showing various applications for the DANOPLUS KIB-006 thermometer, including HVAC, microwave oven, industrial settings, laboratory, aquarium, and refrigeration equipment.

Малюнак: Examples of diverse environments where the thermometer can be effectively utilized.

7. Тэхнічныя характарыстыкі

ПараметрКаштоўнасць
Thermometer Main Unit Temp. Range-200 да 1370°C (ад -328 да 2498°F)
дазвол0.1°C, 0.1°F
Accuracy (under 18-28°C ambient temp.)±(0.3% rdg + 1°C)
K Bead Type Thermocouple Temp. Range-50 да 200°C (ад -58 да 392°F)
Sampлінг -стаўкаProgrammable from 1 second up
Памер LCD (ВxШ)47 х 104 мм (1.85 х 4.1 цалі)
Працоўная тэмператураад 0 да 50°C
Працоўная RH%Вільготнасць <80%
Тэмпература захоўвання-20 да 50°C
Захоўванне RH%Вільготнасць <90%
Памеры (Д х Ш х Т)152 х 100 х 39 мм
Вага300 г (0.66 фунта)
Электразабеспячэнне4 x AA Batteries (included) or 9V adaptor (not included)
Тэхналогія падлучэнняSD-карта
Тып дысплеяВК
Знешні матэрыялПластыкавыя
Нумар мадэліKIB-006
UPC619317589858
Image showing the DANOPLUS KIB-006 thermometer with callouts for its main unit measuring range, K type thermocouple range, big LCD display dimensions, and portable design weight and dimensions.

Image: Detailed specifications and physical dimensions of the thermometer.

8. Тэхнічнае абслугоўванне

  • Уборка: Працірайце прыладу мяккай сухой тканінай. Не выкарыстоўвайце абразіўныя ачышчальнікі або растваральнікі.
  • Замена батарэі: Replace all 4 AA batteries when the low battery indicator appears on the display to ensure accurate readings and proper operation.
  • захоўванне: When not in use for extended periods, remove the batteries and store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Thermocouple Care: Handle thermocouple probes carefully. Avoid bending or kinking the wires excessively, as this can affect accuracy. Replace damaged probes.

9. Выпраўленне непаладак

праблемаМагчымая прычынаРашэнне
Прылада не ўключаеццаРазраджаныя або няправільна ўсталяваныя батарэіПраверце палярнасць батарэек; заменіце іх новымі батарэйкамі тыпу АА.
No temperature reading / "----" on displayThermocouple not connected or faultyEnsure thermocouple is securely connected to the correct channel. Test with another probe if available.
Няправільныя паказанніDamaged thermocouple; incorrect probe type; environmental interferenceInspect probes for damage. Ensure K-type probes are used. Avoid strong electromagnetic fields.
Data not saving to SD cardSD card full or faulty; card not inserted correctly; recording not initiatedCheck SD card capacity. Reinsert SD card. Ensure 'REC' indicator is active. Try a different SD card.
Сігналізацыя не працуеAlarm limits not set; alarm function disabledVerify alarm settings and ensure they are enabled.

10. Гарантыя і падтрымка

The DANOPLUS KIB-006 comes with a standard manufacturer's warranty. For specific warranty details, please refer to the documentation included with your purchase or contact DANOPLUS customer support.

For technical assistance, troubleshooting beyond this manual, or to inquire about replacement parts, please contact your retailer or the manufacturer directly. Contact information can typically be found on the product packaging or the official DANOPLUS webсайт.