1. Прадукт скончыўсяview
The RCYAGO PH-W2839 is a versatile 3-in-1 monitor designed for comprehensive water quality analysis. It accurately measures pH, Oxidation-Reduction Potential (ORP), and temperature, providing real-time data and control capabilities. Equipped with WiFi connectivity, it integrates with the Tuya app for remote monitoring, data logging, and alarm settings, making it ideal for aquariums, aquaculture, and various water management applications.

Малюнак 1: The RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor, showing the main unit, connected pH, ORP, and temperature probes, and the dual-socket power control strip.

Малюнак 2: Key features of the 3-in-1 monitor, including accurate measurement, wide application range, and automatic temperature compensation.
2. Змесціва ўпакоўкі
Калі ласка, пераканайцеся, што ўсе прадметы прысутнічаюць у вашай упакоўцы:
- 1 x WiFi Online pH ORP Temperature Controller Unit
- 1 x pH Electrode
- 1 x ORP Electrode
- 1 х тэмпературны зонд
- 1 x Dual-Socket Power Control Strip
- Calibration Powders (pH 4.01, pH 6.86/7.0, pH 9.18/10.01, ORP 256mV)
- 1 х адаптар сілкавання
- Кіраўніцтва карыстальніка

Малюнак 3: Падрабязны view of the high-precision ORP electrode, pH electrode, temperature electrode, and the power plug included with the device.
3. Настройка і ўстаноўка
Follow these steps to set up your pH ORP Temperature Controller:
- Мантаж кантролера: Choose a suitable location near your water body (aquarium, tank, etc.) and mount the main controller unit securely. Ensure it is protected from direct splashes.
- Connecting Electrodes: Carefully connect the pH electrode, ORP electrode, and temperature probe to their respective BNC connectors and jack on the main controller unit. Ensure connections are firm.
- Connecting Power Control Strip: Plug the dual-socket power control strip into the designated output port on the main controller. This strip will be used to connect external devices (e.g., CO2 solenoid valve, heater) that you wish to control based on pH or ORP levels.
- Размяшчэнне зонда: Submerge the pH electrode, ORP electrode, and temperature probe into the water you intend to monitor. Ensure the sensing parts of the electrodes are fully immersed and positioned to get accurate readings, away from strong currents or air bubbles.
- Падключэнне сілкавання: Plug the main controller's power adapter into a standard electrical outlet. The device will power on.
- WiFi Connection (Tuya App):
- Запампуйце праграму «Tuya Smart» або «Smart Life» з крамы праграм вашай мабільнай прылады (iOS або Android).
- Зарэгіструйцеся альбо ўвайдзіце ў свой рахунак.
- Follow the in-app instructions to add a new device. The controller should enter pairing mode automatically or by pressing the WiFi button.
- Connect the device to your 2.4GHz WiFi network.

Малюнак 4: A typical setup diagram showing the controller connected to a CO2 system and probes immersed in an aquarium.

Малюнак 5: The controller in operation, demonstrating WiFi connectivity and real-time data transfer to a mobile application.
4. Каліброўка
Regular calibration ensures the accuracy of your pH and ORP readings. It is recommended to calibrate the device upon initial setup and periodically thereafter.
4.1. Каліброўка pH
The device supports 3-point pH calibration (pH 7.0, pH 4.01, pH 10.01).
- Prepare fresh pH buffer solutions (pH 7.0, pH 4.01, pH 10.01).
- Rinse the pH electrode with distilled water and gently blot dry.
- Immerse the pH electrode into the pH 7.0 buffer solution.
- Press the 'CAL' button under the pH display on the controller. The device will automatically recognize the buffer and calibrate. Wait for the reading to stabilize.
- Rinse the electrode again.
- Repeat the process for pH 4.01 and pH 10.01 buffer solutions. Ensure to calibrate in ascending or descending order as per device prompts.
4.2. ORP Calibration
The device supports ORP calibration using a 256mV standard solution.
- Prepare a fresh 256mV ORP standard solution.
- Rinse the ORP electrode with distilled water and gently blot dry.
- Immerse the ORP electrode into the 256mV standard solution.
- Press the 'CAL' button under the ORP display on the controller. The device will automatically recognize the standard and calibrate. Wait for the reading to stabilize.

Малюнак 6: Visual guide for the 3-point pH calibration and ORP calibration process using standard buffer solutions.
5. Інструкцыя па эксплуатацыі
5.1. Маніторынг у рэжыме рэальнага часу
Once powered on and probes are immersed, the controller's LCD screen will display real-time pH, ORP, and temperature readings. The WiFi indicator will show connection status.
5.2. Tuya App Functionality
The Tuya app provides advanced monitoring and control features:
- Дадзеныя ў рэжыме рэальнага часу: View current pH, ORP, and temperature readings remotely.
- Гістарычныя дадзеныя: Access daily, weekly, and monthly data logs for trend analysis.
- Налады будзільніка: Set high and low alarm thresholds for pH and ORP. Receive notifications on your mobile device if values exceed or fall below these thresholds.
- Стварэнне разумнай сцэны: Create automated rules (smart scenes) within the Tuya app to control connected devices via the power strip. For example, turn on a CO2 solenoid when pH rises above a certain level.

Малюнак 7: The controller's display and the Tuya app interface, demonstrating real-time monitoring and alarm settings.

Малюнак 8: Illustration of the app's alarm setting capabilities, allowing users to define thresholds and trigger actions.

Малюнак 9: The device provides real-time data transmission, allowing users to view historical data trends over various periods.
6. Тэхнічнае абслугоўванне
Proper maintenance extends the lifespan and ensures the accuracy of your electrodes and controller.
- Ачыстка электродаў: Regularly clean the pH and ORP electrodes with distilled water to remove any buildup or contaminants. For stubborn deposits, use a mild cleaning solution specifically designed for electrodes, following the manufacturer's instructions.
- Захоўванне электродаў: When not in use, store the pH and ORP electrodes in their protective caps filled with a suitable storage solution (e.g., KCL solution or pH 4 buffer). Never store electrodes dry.
- Перакаліброўка: Calibrate the pH and ORP electrodes regularly, especially if you notice inconsistent readings or after cleaning. The frequency depends on usage and water conditions.
- Controller Unit: Keep the main controller unit clean and dry. Avoid exposing it to extreme temperatures or direct sunlight.
7. Выпраўленне непаладак
Калі ў вас узніклі праблемы з прыладай, звярніцеся да наступных распаўсюджаных праблем і рашэнняў:
| праблема | Магчымая прычына | Рашэнне |
|---|---|---|
| Inaccurate pH/ORP readings | Electrodes are dirty or aged; improper calibration; air bubbles on electrode. | Clean electrodes thoroughly; recalibrate the device; gently tap electrodes to dislodge bubbles. Replace electrodes if they are old or damaged. |
| Збой злучэння WiFi | Incorrect WiFi password; device too far from router; 5GHz WiFi network used; router issues. | Ensure correct 2.4GHz WiFi password; move device closer to router; verify router is broadcasting 2.4GHz; restart router and device. |
| Relay output not triggering | Incorrect alarm settings in Tuya app; device not connected to power strip; external device malfunction. | Check and adjust pH/ORP alarm thresholds and smart scene rules in the app; ensure the external device is properly plugged into the control strip and functioning independently. |
| Temperature reading incorrect | Temperature probe not fully immersed or damaged. | Ensure the temperature probe is fully submerged; inspect the probe for physical damage. |
8. Тэхнічныя характарыстыкі
Detailed technical specifications for the RCYAGO PH-W2839 monitor:

Малюнак 10: Скончанаview of the device's measurement ranges, resolutions, and accuracy.
| Параметр | Дыяпазон | дазвол | Дакладнасць |
|---|---|---|---|
| pH | 0.00pH - 14.00pH | 0.01pH | ±0.1 pH |
| ОВП | -2000mV - +2000mV | 1mV | ±5 мВ |
| тэмпература | 0°C - 50°C (32°F - 122°F) | 1.0°C (0.2°F) | ±1.0°C |
- крыніца харчавання: AC 110-240V, 50/60Hz (Specific adapter details may vary)
- Стандарт Wi-Fi: 2.4 ГГц 802.11b/g/n
- Памеры: Approximately 11.1 x 8.11 x 2.99 inches (Controller unit)
- Вага: Прыблізна 2.34 фунтаў
9. Дадаткі
The RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor is suitable for a wide range of water quality monitoring applications, including but not limited to:
- Aquariums (Freshwater and Seawater)
- Aquaculture and Fish Tanks
- Hydroponics and Plant Cultivation
- Swimming Pools and Spas
- Domestic Water Quality Testing
- Laboratory Research and Testing

Малюнак 11: The versatility of the monitor across different water quality monitoring scenarios.




10. Гарантыя і падтрымка
This product comes with a standard manufacturer's warranty. For specific warranty terms, duration, and to register your product, please refer to the warranty card included in your package or visit the official RCYAGO webсайт.
For technical support, troubleshooting assistance, or any inquiries regarding your RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor, please contact RCYAGO customer service through the contact information provided on their official webсайце або ў дакументацыі да вашага прадукту.