Elitech Tlog 10H

Elitech Tlog 10H Digital Temperature and Humidity Data Logger User Manual

1. Уводзіны

This manual provides comprehensive instructions for the Elitech Tlog 10H Digital Temperature and Humidity Data Logger. It covers device setup, operation, data retrieval, maintenance, and troubleshooting. Please read this manual thoroughly before using the device to ensure proper functionality and accurate data collection.

Elitech Tlog 10H Digital Temperature and Humidity Data Logger

Фронт view of the Elitech Tlog 10H digital data logger, displaying its screen and control buttons.

2. Асаблівасці прадукту

  • Універсальнае прымяненне: The Elitech Tlog 10H is suitable for various applications including life science, food cold chain management, and industrial environments. It complies with FDA 21 CFR Part 11 standards.
  • Automatic PDF Report Generation: The device generates a PDF report with embedded data directly, requiring no additional software for access.
  • On-Screen Data Display: The device's screen displays current temperature, maximum/minimum values, current date, and recording points. Temperature units (Fahrenheit/Celsius) are switchable.
  • Anti-Touch Button Design: Features a design that minimizes accidental button presses during transport, preventing unintended operations.
  • Наладжвальныя параметры: Users can set temperature units, alarm ranges, and logging intervals. Additional functionalities are available through the Elitechlog software.

3. Кампаненты прадукту

Labeled diagram of Elitech Tlog 10H components

Detailed diagram of the Elitech Tlog 10H data logger, labeling its internal sensor, LED indicator, Start/Stop button, and USB port.

  • Унутраны датчык: Вымярае тэмпературу і вільготнасць.
  • Святлодыёдны індыкатар: Provides status updates (e.g., recording, alarm).
  • Кнопка: Used for Start, Stop, Status, and Mark functions.
  • Порт USB: For connecting to a computer to download data and configure settings.

4. Тэхнічныя характарыстыкі

Dimensions and technical specifications of the Elitech Tlog 10H data logger

A diagram showing the dimensions and key specifications of the Elitech Tlog 10H, including its measurement range and accuracy for temperature and humidity.

СпецыфікацыяДэталь
Нумар мадэліТлог 10 гадзін
Measurement Range (Temperature)Ад -40°F да 185°F (ад -30°C да 70°C)
Measurement Range (Humidity)0% RH да 100% RH
Дакладнасць (тэмпература)±0.9°F (-4°F~104°F); ±0.5°C (-20°C~40°C); ±1.8°F (-58°F~185°F); ±1.0°C (-50°C~85°C)
Accuracy (Humidity)±3%RH (25°C; 20%~80%RH); ±5%RH (others)
Ёмістасць памяці32,000 XNUMX кропак даных
Тып дысплеяЛічбавы
СувязьUSB
акумулятар1 літый-металічная батарэя (у камплекце)
Знешні матэрыялПластыкавыя
АсаблівасцьШматразовы
Памеры (прыбл.)Height: 3.8 in, Width: 1.7 in, Thickness: 0.5 in
АдпаведнасцьFDA 21 CFR Part 11

5. Настройка

5.1 Initial Device Preparation

  1. Праверка батарэі: The device comes with a pre-installed Lithium Metal battery. Ensure the battery is securely in place.
  2. Ахоўная плёнка: Remove any protective film from the screen before use.

5.2 Software Installation (Optional for Advanced Settings)

While the device generates automatic PDF reports without software, for advanced configuration and data analysis, download the Elitechlog software from the official Elitech webсайт.

  • Visit the Elitech website and navigate to the support or download section.
  • Download and install the Elitechlog software compatible with your operating system.

5.3 Parameter Configuration (Using Elitechlog Software)

Connect the Tlog 10H to your computer via the USB port. Open the Elitechlog software to configure the following parameters:

  • Інтэрвал рэгістрацыі: Set how frequently the device records data (e.g., every 10 minutes, 30 minutes).
  • Дыяпазон сігналізацыі: Define upper and lower temperature and humidity limits for alarms.
  • Адзінка вымярэння тэмпературы: Select between Celsius (°C) and Fahrenheit (°F).
  • Рэжым запуску: Configure how recording begins (e.g., manual button press, delayed start).
  • Рэжым прыпынку: Configure how recording ends (e.g., manual button press, full memory, specific time).
Elitechlog software features for data logger management

An infographic detailing the capabilities of the Elitechlog software, including data query, storage, chart comparison, temperature unit switch, settable alarm range, FDA 21 CFR Part 11 compliance, data graph visibility, and data export options.

6. Інструкцыя па эксплуатацыі

6.1 Starting a Recording Session

Націсніце і ўтрымлівайце СТАРТ button for approximately 3 seconds until the 'REC' indicator appears on the screen, confirming that recording has begun.

6.2 Stopping a Recording Session

Націсніце і ўтрымлівайце СТОП button for approximately 3 seconds until the 'END' indicator appears on the screen, confirming that recording has stopped.

6.3 Viewing Data on Screen

Каротка націсніце СТАРТ button to cycle through various display modes, including current temperature, current humidity, maximum/minimum recorded values, and remaining battery life.

6.4 Switching Temperature Units

While the device is not recording, briefly press both the СТАРТ і СТОП buttons simultaneously to toggle between Celsius (°C) and Fahrenheit (°F).

7. Кіраванне дадзенымі

7.1 Automatic PDF Report Generation

After stopping a recording session, connect the Tlog 10H to a computer's USB port. The device will automatically generate a PDF report containing all recorded data. This report can be saved and viewed without installing any special software.

Elitech Tlog 10H showing automatic PDF report generation and USB connectivity

An image illustrating the Elitech Tlog 10H connected via USB to a laptop, highlighting its automatic PDF report generation and plug-and-play functionality.

7.2 Using Elitechlog Software for Advanced Analysis

For more detailed data analysis, chart comparison, and data export options (e.g., PDF, Excel), use the Elitechlog software. Connect the device to your computer and open the software to access these features.

8. Тэхнічнае абслугоўванне

8.1 Ачыстка

Працірайце прыладу мяккай сухой тканінай. Не выкарыстоўвайце абразіўныя ачышчальнікі і не апускайце прыладу ў ваду.

8.2 Замена батарэі

The device uses a Lithium Metal battery. If the battery indicator shows low power, replace the battery with a new one of the same type. Refer to the device's battery compartment for specific instructions on replacement.

8.3 Захоўванне

Store the data logger in a cool, dry place away from direct sunlight and extreme temperatures when not in use.

9. Выпраўленне непаладак

  • Device not starting: Ensure the battery has sufficient charge. Press and hold the START button firmly for 3 seconds.
  • No data on screen: Check if the device is in recording mode. If not, start a new recording session.
  • Unable to generate PDF report: Ensure the device is properly connected to the USB port of your computer. Verify that the recording session has been stopped.
  • Няправільныя паказанні: Ensure the sensor is not obstructed and the device is placed in an environment suitable for its specified measurement range.

10. Сцэнарыі прымянення

Application scenarios for Elitech Tlog 10H data logger

Images depicting various applications for the Elitech Tlog 10H data logger, such as in cold boxes, refrigerated trucks, cold chain containers, and distribution centers.

The Elitech Tlog 10H is designed for monitoring temperature and humidity in various environments, including:

  • Cold Boxes
  • Refrigerated Trucks
  • Cold Chain Containers
  • Размеркавальныя цэнтры
  • Laboratories and Life Science applications

11. Гарантыя і падтрымка

11.1 Інфармацыя аб гарантыі

Specific warranty details for the Elitech Tlog 10H are typically provided at the point of purchase or on the official Elitech webсайт. Калі ласка, захавайце пацвярджэнне пакупкі для прэтэнзій па гарантыі.

11.2 Падтрымка кліентаў

For technical assistance, troubleshooting, or further inquiries, please contact Elitech customer support. You can find contact information and additional resources on the official Elitech webсайт: Elitech Store on Amazon