OREiN OL17004

OREiN Bathroom Exhaust Fan with LED Light User Manual

Model: OL17004 (110 CFM)

Уводзіны

This manual provides detailed instructions for the installation, operation, and maintenance of your OREiN Bathroom Exhaust Fan with LED Light, Model OL17004. Please read this manual thoroughly before installation and use to ensure proper function and safety. Keep this manual for future reference.

OREiN Bathroom Exhaust Fan with LED Light, showing the fan unit with its white light cover and the three selectable color temperatures (3000K, 4000K, 5000K) at the bottom.

Image: OREiN Bathroom Exhaust Fan with LED Light, showcasing its design and adjustable color temperature options.

Інфармацыя па бяспецы

ПАПЯРЭДЖАННЕ: Каб знізіць рызыку пажару, паражэння электрычным токам або траўміравання людзей, выконвайце наступнае:

  • Install this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
  • Before servicing or cleaning, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, на сэрвісную панэль.
  • Работы па мантажы і пракладцы электраправодкі павінны выконвацца кваліфікаванымі асобамі ў адпаведнасці з усімі дзеючымі кодэксамі і стандартамі, уключаючы будаўнічыя нормы і стандарты супрацьпажарнай бяспекі.
  • Дастатковую колькасць паветра неабходна для правільнага гарэння і адводу газаў праз дымавую трубу (комін) паліўнага абсталявання, каб прадухіліць зваротную цягу. Выконвайце рэкамендацыі вытворцы ацяпляльнага абсталявання і стандарты бяспекі, такія як апублікаваныя Нацыянальнай асацыяцыяй супрацьпажарнай аховы (NFPA), Амерыканскім таварыствам інжынераў па ацяпленні, ахаладжэнні і кандыцыянаванні паветра (ASHRAE), а таксама мясцовымі ўладамі.
  • Пры выразанні або свідраванні сцяны ці столі не пашкоджвайце электраправодку і іншыя схаваныя камунікацыі.
  • Канальныя вентылятары заўсёды павінны выводзіцца на вуліцу.
  • Гэта прылада не прызначана для выкарыстання на кухнях.
  • Не выкарыстоўвайце гэты вентылятар з любым цвёрдацельным прыладай рэгулявання хуткасці.

Змест пакета

Перад пачаткам усталёўкі пераканайцеся, што ўсе кампаненты наяўныя:

  • OREiN Bathroom Exhaust Fan Unit (Housing with Motor and Duct Connector)
  • Крышка святлодыёднага святла
  • Мантажны кранштэйн
  • Wire Connectors (Wago-style)
  • Крапежныя шрубы
Выбухнуў view of OREiN Bathroom Exhaust Fan components, showing the fan housing, mounting bracket, and light cover, along with small parts like wire connectors and screws.

Image: Components included with the OREiN Bathroom Exhaust Fan.

Тэхнічныя характарыстыкі

АсаблівасцьСпецыфікацыя
МаркаOREiN
Назва мадэліOL17004
Ёмістасць паветранага патоку110 CFM (кубічных футаў у хвіліну)
Узровень шуму2.0 Сон
Ватtage27 Watts (Total, Fan + Light)
Святлоаддача1500 люмен
Каляровая тэмпература (CCT)3000K (Soft White), 4000K (Bright White), 5000K (Daylight) Selectable
Начнік2200 тыс
тtage120 вольт
Housing Dimensions (L x W x H)7.68" x 7.55" x 6.42"
Light Cover Size9.8 цалі х 9.8 цалі
Ceiling Opening Size8.11 цалі х 7.48 цалі
Памер раздыма паветравода4 цаляў (круглы)
СертыфікатыETL, FCC Listed
Detailed product dimensions for the OREiN Bathroom Exhaust Fan, showing the housing, light cover, and required ceiling opening sizes in inches.

Image: Product dimensions and required ceiling opening for installation.

Настройка і ўстаноўка

Неабходныя інструменты: Screwdriver, Wire Strippers, Drill, Measuring Tape, Utility Knife, Safety Glasses, Gloves.

Важна: Перад пачаткам усталёўкі пераканайцеся, што электрычнасць адключана з дапамогай аўтаматычнага выключальніка.

  1. Падрыхтуйце адтуліну ў столі: Create a ceiling opening of 8.11" x 7.48". Ensure there is sufficient space above the ceiling for the fan housing (7.68" x 7.55" x 6.42").
  2. Усталюйце корпус:
    • Attach the mounting bracket to the ceiling joists. The bracket is designed for easy installation between joists.
    • Slide the fan housing into the mounting bracket. Secure the housing to the bracket using the provided screws or by nailing/screwing directly to the joist if preferred.
  3. Падключэнне паветраводаў: Connect a 4-inch round duct to the fan's duct connector. Ensure the duct is securely fastened and sealed to prevent air leakage. Vent the ductwork to the outdoors.
  4. Электраправодка:
    • Route the electrical supply wires (120V AC) to the fan housing.
    • Connect the fan's wires to the household wiring using the provided wire connectors. Follow the wiring diagram below.
    • Забяспечце належнае зазямленне.
    • The fan and light can be wired to separate switches for independent control. The LED light wires cannot be connected to a dimmer switch.
  5. Усталяваць асвятляльнае пакрыццё: Once wiring is complete and secured, attach the LED light cover to the fan housing. Ensure it clicks into place or is securely fastened according to the design.
Wiring diagram for the OREiN Bathroom Exhaust Fan with Light, showing connections for ground, fan switch, and light switch to a 120V AC line. Also shows the fan's install size of 8.11 by 7.48 inches.

Image: Electrical wiring diagram and installation dimensions.

Інструкцыя па эксплуатацыі

Праца вентылятара

The exhaust fan operates at 110 CFM to effectively remove moisture and odors from your bathroom. It features a low noise level of 2.0 sones for quiet performance.

  • Turn on the dedicated fan switch to activate the exhaust fan.
  • Turn off the fan switch to deactivate the fan.
OREiN Bathroom Exhaust Fan installed in a ceiling, highlighting its features: 110 CFM airflow, less than 2.0 Sones noise level, 26W power consumption, and 3 CCT options with 1500 lumens.

Image: Installed fan highlighting key performance metrics.

Праца святлодыёднага святла

The integrated LED light offers adjustable color temperature and a nightlight function.

  • Adjusting Color Temperature (CCT):

    The fan features a toggle switch on the back of the unit (accessible before final installation of the light cover) to select your desired color temperature: 3000K (Soft White), 4000K (Bright White), or 5000K (Daylight). Set this switch to your preferred CCT before installing the light cover.

    Тры эксamples of the OREiN Bathroom Exhaust Fan's LED light at different color temperatures: 3000K (warm white), 4000K (neutral white), and 5000K (cool daylight), all at 1500 lumens. A small toggle switch is shown for CCT selection.

    Image: Demonstrates the three selectable color temperatures of the LED light.

  • Рэжым начнога святла:

    The fan includes a 2200K nightlight feature. To activate or cycle through the nightlight mode, quickly turn the light switch OFF and then ON again within 2 seconds. This action will switch between the main light and the nightlight mode.

    A bathroom scene illuminated by the OREiN Bathroom Exhaust Fan's 2200K nightlight, showing a soft, warm glow. Text indicates that cycling the light switch within 2 seconds changes to nightlight mode.

    Image: The 2200K nightlight function in a bathroom setting.

Тэхнічнае абслугоўванне

Regular maintenance ensures optimal performance and longevity of your exhaust fan.

  • Cleaning the Light Cover:
    • Turn off power at the circuit breaker before cleaning.
    • Carefully remove the light cover.
    • Wipe the light cover with a soft, damp тканіна. Не выкарыстоўвайце абразіўныя ачышчальнікі.
    • Allow the cover to dry completely before reattaching.
  • Cleaning the Fan Grille/Housing:
    • With the light cover removed and power off, gently vacuum or wipe away any dust or debris from the fan grille and accessible parts of the housing.
    • Do not spray water directly into the fan motor or electrical components.
  • Святлодыёдная крыніца святла: The LED light source is integrated and designed for long life. It is not user-replaceable. If the LED light fails, contact customer support.

Ліквідацыю непаладак

праблемаМагчымая прычынаРашэнне
Вентылятар не працуе.Няма электразабеспячэння; няспраўная праводка; няспраўны выключальнік.Check circuit breaker. Ensure all wire connections are secure. Test switch functionality.
Святло не ўключаецца.No power supply; loose wiring; faulty switch; CCT toggle switch not set.Check circuit breaker. Ensure all wire connections are secure. Test switch functionality. Verify the CCT toggle switch on the fan unit is set to a valid position (3000K, 4000K, or 5000K).
Вентылятар шуміць або празмерна вібруе.Loose mounting; debris in fan blades; motor issue.Ensure fan housing is securely mounted. Turn off power and inspect fan blades for obstructions. If noise persists, contact customer support.
Poor ventilation/steam not clearing.Blocked ductwork; improper duct installation; fan motor issue.Check ductwork for kinks or blockages. Ensure duct is properly sealed and vented outdoors. Verify fan motor is running at full speed.
Light color temperature is incorrect or stuck.CCT toggle switch not set correctly.Turn off power, remove light cover, and adjust the CCT toggle switch on the fan unit to your desired setting. Reinstall cover and restore power.
Nightlight function not working.Incorrect switching sequence.Ensure you are cycling the light switch OFF and ON again within 2 seconds to activate the nightlight mode.

Гарантыя і падтрымка

For warranty information or technical assistance, please contact OREiN customer support. Refer to your purchase documentation for specific warranty terms and conditions.

Кантактная інфармацыя:

  • For support, please visit the OREiN store on Amazon: OREiN Amazon Store
  • Alternatively, search for "OREiN" online to find official contact channels.

Additional resources, including a detailed Installation Manual and User Guide, may be available in PDF format:

© 2025 OREiN. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.