Zurn P6900-B-L

Zurn P6900-B-L AquaSense Electronics Module with Solenoid Instruction Manual

Model: P6900-B-L | Brand: Zurn

1. Уводзіны

The Zurn P6900-B-L AquaSense Electronics Module with Solenoid is a replacement component designed for Zurn AquaSense sensor faucets, specifically models Z6912, Z6913, Z6915, and Z6920. This module integrates the solenoid valve, battery pack, and the necessary wiring to connect to the faucet's infrared proximity sensor, enabling hands-free operation. This manual provides instructions for proper installation, operation, and maintenance of the module.

2. Інфармацыя па бяспецы

  • Always turn off the water supply to the faucet before beginning any installation or maintenance.
  • Disconnect electrical power if applicable before servicing.
  • Апранайце адпаведныя сродкі індывідуальнай абароны, такія як ахоўныя акуляры і пальчаткі.
  • Пераканайцеся, што ўсе злучэнні надзейныя, каб пазбегнуць уцечак.
  • Утылізуйце старыя батарэі адказна ў адпаведнасці з мясцовымі правіламі.

3. Змесціва ўпакоўкі

Перад пачаткам усталёўкі пераканайцеся, што ўсе кампаненты наяўныя:

  • Zurn P6900-B-L AquaSense Electronics Module with Solenoid
  • Battery Pack (integrated)
  • 4 шчолачныя батарэйкі тыпу АА (у камплекце)
  • Connecting Wire to Faucet Sensor
  • Small Hex Key/Wrench (for securing connections, if applicable)
  • O-ring (for sealing connections, if applicable)
Zurn P6900-B-L Electronics Module with included batteries and hex key
Image 3.1: Zurn P6900-B-L Electronics Module with included batteries and hex key. This image displays the main module unit, four AA batteries, and a small hex key, which are typically included in the package.

4. Настройка і ўстаноўка

Follow these steps to install the Zurn P6900-B-L Electronics Module:

  1. Выключыце падачу вады: Locate the main water shut-off valve for the faucet and turn it off completely.
  2. Disconnect Old Module (if replacing): Carefully disconnect the existing electronics module from the faucet sensor and water lines. Be prepared for residual water.
  3. Падрыхтуйце новы модуль: Ensure the new P6900-B-L module has the included 4 AA alkaline batteries properly installed in the battery compartment.
  4. Падключэнне вадаправодаў: Attach the solenoid valve portion of the new module to the appropriate hot and cold water supply lines. Use thread sealant tape or pipe dope as recommended by local plumbing codes. Ensure connections are hand-tight, then use a wrench for a final quarter-turn, avoiding overtightening.
  5. Connect Sensor Wire: Carefully connect the wire from the electronics module to the faucet's infrared proximity sensor. The connector pins are delicate; align them precisely to avoid bending. Removing any rubber o-ring on the connector might assist in feeling for a solid connection, as a coupler nut typically secures the pieces.
  6. Бяспечны модуль: Mount or secure the electronics module in a suitable location, typically under the sink, ensuring it is protected from moisture and easily accessible for future maintenance.
  7. Аднаўленне водазабеспячэння: Slowly turn the main water supply back on and check for any leaks at all connection points.
  8. Тэставая аперацыя: Activate the faucet sensor to verify proper water flow and shut-off.
Ніжні бок view of Zurn P6900-B-L Electronics Module showing connection points
Малюнак 4.1: Ніжні бок view of Zurn P6900-B-L Electronics Module showing connection points. This image highlights the water inlet and outlet connections, as well as the sensor wire port on the module.

5. Інструкцыя па эксплуатацыі

The Zurn AquaSense Electronics Module controls water flow in conjunction with the faucet's infrared proximity sensor. To operate the faucet:

  • Актывацыя: Place your hands within the detection range of the faucet's sensor. The sensor will detect your presence.
  • Паток вады: Upon detection, the electronics module will activate the solenoid valve, allowing water to flow from the faucet.
  • Дэактывацыя: Remove your hands from the sensor's detection range. The module will then close the solenoid valve, stopping the water flow.

The system is designed for hands-free operation, promoting hygiene and water conservation.

6. Тэхнічнае абслугоўванне

Regular maintenance ensures optimal performance and longevity of your Zurn AquaSense Electronics Module.

6.1. Замена батарэі

The module is powered by 4 AA alkaline batteries. When the batteries are low, the faucet may exhibit inconsistent operation or cease to function. To replace the batteries:

  1. Выключыце падачу вады: Адключыце падачу вады ў кран.
  2. Доступ да батарэйнага адсека: Locate the battery compartment on the electronics module. This is typically secured with a cover.
  3. Выдаліць старыя батарэі: Open the compartment and remove the old AA batteries.
  4. Устаўце новыя батарэі: Устаўце чатыры новыя шчолачныя батарэйкі тыпу АА, сачыце за правільнай палярнасцю (+/-).
  5. Бяспечны адсек: Зачыніце і замацуйце вечка батарэйнага адсека.
  6. Аднавіць падачу вады і правесці выпрабаванне: Turn the water supply back on and test the faucet's operation.

6.2. Уборка

Periodically inspect the module and connections for any signs of corrosion or debris. Clean the exterior of the module with a soft, damp тканіна. Не выкарыстоўвайце абразіўныя ачышчальнікі або растваральнікі.

7. Выпраўленне непаладак

If your Zurn AquaSense faucet is not functioning correctly, refer to the following table for common issues and solutions:

праблемаМагчымая прычынаРашэнне
No water flow when sensor is activatedАкумулятары разрядились або разрядились
Water supply off
Sensor wire disconnected or damaged
Няспраўнасць электрамагнітнага клапана
Заменіце батарэі
Check water supply valve
Verify sensor wire connection
Contact Zurn support for solenoid replacement
Water flows continuouslyДатчык забіты або няспраўны
Solenoid valve stuck open
Clean sensor lens; check for obstructions
Contact Zurn support for solenoid inspection/replacement
Слабы паток вадыНізкі ціск вады
Аэратар забіты
Solenoid partially obstructed
Check building water pressure
Clean or replace faucet aerator
Contact Zurn support for solenoid inspection
Датчык не рэагуеАкумулятары разрядились або разрядились
Sensor lens dirty
Sensor wire disconnected or damaged
Заменіце батарэі
Ачысціце лінзу датчыка
Verify sensor wire connection

8. Тэхнічныя характарыстыкі

АсаблівасцьДэталь
Назва мадэліP6900-B-L
Нумар дэталіP6900-B-L
Вага прадмета1.12 фунта
Памеры прадукту6 х 4 х 3.2 цалі
МатэрыялПластык, метал
Батарэі4 шчолачныя батарэйкі тыпу АА (у камплекце)
Compatible FaucetsZ6912, Z6913, Z6915, Z6920 Series
АсаблівасцьБез свінцу
UPC670240576582

9. Гарантыя і падтрымка

The Zurn P6900-B-L AquaSense Electronics Module is covered by a limited manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your original Zurn product or visit the official Zurn webсайт.

For technical support, replacement parts, or further assistance, please contact Zurn Customer Service:

  • Webсайт: www.zurn.com
  • Кантактная інфармацыя: Refer to the 'Contact Us' section on the Zurn webсайт з нумарамі тэлефонаў і падтрымкай па электроннай пошце.

© 2024 Zurn Industries. All rights reserved.