Reznor UDXC-60
Reznor UDXC-60 Natural Gas Unit Heater Instruction Manual
Model: UDXC-60 | Brand: Reznor
1. Уводзіны
The Reznor UDXC series natural gas heaters are designed to provide efficient and reliable heating for a variety of indoor spaces. These units are ideal for commercial, industrial, and residential applications such as garages, workshops, warehouses, and factories. The UDXC-60 model, with its 60,000 BTU output, offers quiet forced air heating, ensuring a comfortable environment while minimizing operational noise.
This manual provides essential information for the safe and effective installation, operation, and maintenance of your Reznor UDXC-60 unit heater. Please read all instructions thoroughly before proceeding with installation or use.

Малюнак 1: Спераду view of the Reznor UDXC-60 Natural Gas Unit Heater.
2. Інфармацыя па бяспецы
ПАПЯРЭДЖАННЕ: Гэты прадукт можа падвергнуць вас уздзеянню хімічных рэчываў, у тым ліку свінцу і злучэнняў свінцу, якія, як вядома ў штаце Каліфорнія, выклікаюць рак і прыроджаныя дэфекты або іншыя пашкоджанні рэпрадуктыўнай сістэмы. Для атрымання дадатковай інфармацыі перайдзіце да www.P65Warnings.ca.gov.
- Installation and service must be performed by a qualified installer, service agency, or gas supplier. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death.
- Ensure adequate ventilation in the installation area to prevent carbon monoxide buildup.
- Не захоўвайце і не выкарыстоўвайце бензін або іншыя лёгкаўзгаральныя пары і вадкасці паблізу гэтага або любога іншага прыбора.
- Keep the area around the heater clear and free from combustible materials.
- Always follow all local and national codes and regulations for gas appliance installation and operation.
3. Настройка і ўстаноўка
The Reznor UDXC-60 unit heater is designed for versatile mounting and venting options. Professional installation is highly recommended to ensure safety and compliance with all applicable codes.
3.1 Мантаж
The unit features threaded-nut retainers at four suspension points, allowing for secure installation as a ceiling-mounted hanging furnace or a wall-mounted heater. Mounting brackets are sold separately. Ensure the mounting structure can safely support the weight of the unit.

Figure 2: Unit heater showing suspension points and external gas connection.

Малюнак 3: Выпample of a mounting bracket (sold separately).
3.2 Вывядзенне паветра
Proper venting is crucial for safe operation. The UDXC-60 is compatible with:
- Category 1 double wall B-vent when venting vertically out of a roof.
- Category 3 single wall vent pipe when vented horizontally through a sidewall.
Consult the detailed installation instructions provided with the unit for specific venting requirements and clearances.
3.3 Электрычнае падключэнне
The unit requires a 24V electrical connection, accessible via an external terminal strip. All electrical wiring must comply with local and national electrical codes and be performed by a licensed electrician.

Малюнак 4: Закончанаview of simplified installation features including electrical connections.
4. Інструкцыя па эксплуатацыі
The Reznor UDXC-60 is designed for efficient and quiet operation, providing consistent heat for your space.
4.1 Узроўні нагрэву
The UDXC-60 offers two heating output levels to adapt to varying temperature needs:
- Слабы агонь: 34,860 BTU, suitable for milder cool days.
- Высокі агонь: 49,800 BTU, for the coldest times of the year.
The unit achieves an 83% thermal efficiency rating, ensuring effective heat delivery.

Figure 5: Illustration of the heater's heating flexibility with two BTU outputs.
4.2 Quiet Forced Air Heating
UDXC models are engineered for quiet operation, featuring a vibration/noise isolated low static pressure axial propeller fan and a power venting system. This design provides optimal performance in most indoor environments without excessive noise, making them ideal for spaces where sound levels are a concern.

Figure 6: Diagram illustrating efficient air circulation and heat distribution.

Figure 7: Key features highlighting quiet operation and durable design.
5. Тэхнічнае абслугоўванне
Regular maintenance ensures the longevity and efficient operation of your Reznor UDXC-60 heater. Always disconnect power and gas supply before performing any maintenance.
- Штогадовая праверка: It is recommended to have a qualified service technician inspect the unit annually, especially before the heating season.
- Уборка: Keep the fan blades and heat exchanger clean from dust and debris. The improved cabinet design with a removable front face and a hinged access door panel with a quarter-turn latch facilitates easier access for cleaning and inspection.
- Vent System Check: Periodically inspect the vent system for any obstructions, leaks, or damage.
- Gas Connection Check: Ensure all gas connections are secure and free from leaks.
6. Выпраўленне непаладак
The Reznor UDXC-60 features an integrated circuit board with a 7-segment display and a status-indicating LED for simplified troubleshooting. Refer to the unit's display for error codes and status indicators.
- No Heat/Unit Not Starting:
- Праверце наладу тэрмастата.
- Verify the gas supply is on.
- Ensure the power supply is connected and the built-in disconnect switch is engaged.
- Check the 7-segment display for error codes.
- Незвычайныя шумы:
- Inspect the fan for obstructions or damage.
- Ensure the unit is securely mounted and free from vibrations.
- Слабая прадукцыйнасць ацяплення:
- Check for proper air circulation and clear any obstructions around the unit.
- Ensure the correct heating level (low/high fire) is selected for the ambient temperature.
For persistent issues or complex problems, contact a qualified service technician.
7. Тэхнічныя характарыстыкі
| Асаблівасць | Дэталь |
|---|---|
| Марка | Reznor (Distributed by 1HVAC) |
| Нумар мадэлі | UDXC-60 |
| Цеплааддача | 60,000 BTU (Two levels: Low Fire 34,860 BTU / High Fire 49,800 BTU) |
| Цеплавая эфектыўнасць | 83% |
| Тып паліва | Прыродны газ |
| Выкарыстанне ў памяшканні/на вуліцы | У памяшканні |
| Памеры прадукту (Д х Ш х У) | 32.72" x 27" x 16.75" |
| Тып мацавання | Ceiling Mount, Wall Mount (using suspension points) |
| Тып нумара | Garage, Commercial, Industrial |
| Асаблівасць | Fast Heating, Quiet Operation, Integrated Circuit Board with Display |
| Цеплаабменнік | TCORE2 Titanium-Stabilized Aluminized Steel |
| Дата першай даступнасці | 14 ліпеня 2023 г |

Figure 8: Key dimensions of the UDXC-60 unit heater.

Малюнак 9: Закончанаview of standard features including efficiency and heat exchanger material.
8. Інфармацыя аб гарантыі
The Reznor UDXC-60 unit heater comes with the following warranty coverage:
- 9 гады: Heat Exchanger, Burner, and Flue Collection Box Assembly.
- 4 гады: All Electrical and Mechanical Components.
To ensure a valid warranty, installation must comply with all local and state codes. Retain your proof of purchase and installation records for warranty claims.
9. Падтрымка і кантакты
For further assistance, technical support, or to purchase accessories and replacement parts, please refer to the contact information provided by your retailer or visit the official Reznor website. Always provide your model number (UDXC-60) when seeking support.
For more information about Reznor's commitment to quality and innovation, you can visit the 1HVAC Store on Amazon.
Звязаныя дакументы - UDXC-60
![]() |
Reznor Gas Conversion Kit Installation for Gas-Fired Unit Heaters This document provides installation instructions for Reznor gas conversion kits for various gas-fired unit heater models, including UBX, UBXC, UBZ, UDX, UDXC, UDZ, UDAP, UDAS, UDBP, and UDBS. It details component selection, safety precautions, and installation steps for converting between natural gas and propane, as well as for high-elevation installations. |
![]() |
Reznor Ceiling Suspension Kit Installation Guide for Electric and Gas-Fired Unit Heaters Installation instructions and component details for the Reznor CK22 Ceiling Suspension Kit, compatible with EHU electric and UDXC, UDX, UDZ gas-fired unit heaters. Learn how to safely mount your Reznor heater. |
![]() |
Кіраўніцтва па ўсталёўцы камплекта рэле Reznor для кіравання некалькімі прыладамі (CL31/CL32) Поўнае кіраўніцтва па ўсталёўцы рэлейных камплектаў Reznor CL31 і CL32, якое дазваляе кіраваць некалькімі прыладамі для розных электрычных і газавых абагравальнікаў Reznor. Уключае спісы кампанентаў, падрабязныя этапы ўсталёўкі і спецыфікацыі падключэння. |
![]() |
Кіраўніцтва па ўсталёўцы камплекта вертыкальных жалюзі Reznor для газавых абагравальнікаў (OPT-CD1) Інструкцыя па ўсталёўцы камплекта вертыкальных жалюзі Reznor OPT-CD1, прызначанага для газавых ацяпляльных прыбораў (мадэлі UBX, UBXC, UBZ, UDX, UDXC, UDZ, UEZ). Уключае спіс кампанентаў і пакрокавае кіраўніцтва па зборцы. |
![]() |
VIVOSUN Fan-Forced Heater User Manual - Installation, Operation, and Safety Guide Comprehensive user manual for the VIVOSUN Fan-Forced Heater, covering important instructions, safety information, specifications, installation, operation, maintenance, troubleshooting, and warranty details. |
![]() |
Reznor UBXC/UDXC Gas-Fired Unit Heater Replacement Parts Manual This manual provides detailed replacement parts information for Reznor UBXC and UDXC series gas-fired unit heaters. It includes sections on serial number decoding, electrical components, fan and motor assemblies, blower assemblies, cabinet components, heat exchanger and burner assemblies, venter and flue wrapper components, and various accessories and options. |
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.