1. Уводзіны
Thank you for choosing Bellababy 19mm Flange Inserts. These inserts are designed to provide a more comfortable and efficient pumping experience by reducing the tunnel size of your existing Bellababy wearable pump flanges. This manual provides essential information for the proper use, care, and maintenance of your flange inserts.
Image showing the two 19mm flange inserts, designed to reduce the tunnel size of larger breast pump flanges for a more comfortable and efficient pumping experience.
2. Змесціва ўпакоўкі
Калі ласка, праверце ўпакоўку, каб пераканацца ў наяўнасці ўсіх прадметаў:
- 2 x Bellababy 19mm Flange Inserts
3. Сумяшчальнасць
These 19mm flange inserts are specifically designed for use with Bellababy Wearable Pumps models BLA8040 and BLA8042. Ensure your pump model is compatible before use.
4. Настройка і ўстаноўка
Follow these steps to properly install the flange inserts into your Bellababy wearable pump flanges:
- Ачыстка і дэзінфекцыя: Before first use, and after each subsequent use, thoroughly clean and sanitize the flange inserts as described in the Maintenance section.
- Identify Flange Size: Ensure you are using the correct size flange insert (19mm) for your nipple diameter.
- Insert into Flange: Gently press the 19mm flange insert into the larger Bellababy pump flange. The insert should fit snugly and securely within the existing flange tunnel.
- Check for Secure Fit: Verify that the insert is fully seated and there are no gaps between the insert and the original flange. A secure fit is crucial for effective suction and comfort.
- Збярыце помпа: Once the inserts are in place, assemble the rest of your Bellababy wearable pump components as per your pump's instruction manual.
5. Эксплуатацыя (Выкарыстанне)
Once the flange inserts are correctly installed, operate your Bellababy wearable pump as you normally would. The inserts will reduce the tunnel size, providing a more appropriate fit for smaller nipple diameters. This can help prevent discomfort, improve milk expression, and protect nipple tissue during pumping sessions.
- Праверка камфорту: During your first pumping session with the inserts, pay close attention to your comfort level. If you experience pain or discomfort, discontinue use and re-evaluate your flange size.
- Nipple Movement: Your nipple should move freely within the tunnel of the insert without excessive friction or swelling.
6. Maintenance, Cleaning, and Care
Proper cleaning and sanitization are essential for hygiene and product longevity.
Пасля кожнага выкарыстання:
- разабраць: Remove the flange inserts from the pump flanges.
- Паласканне: Rinse all parts under cool running water to remove milk residue.
- мыць: Wash the inserts with warm, soapy water using a clean brush. Ensure all milk film is removed.
- Старанна прамыйце: Rinse again under running water to remove all soap residue.
- Санітаваць:
- Кіпячэнне: Place inserts in a pot of boiling water for 5 minutes. Ensure parts do not touch the bottom or sides of the pot to prevent damage.
- Паравы стэрылізатар: Use a microwave or electric steam sterilizer according to the manufacturer's instructions.
- Сушка на паветры: Place cleaned and sanitized parts on a clean paper towel or drying rack in a well-ventilated area. Do not use a cloth towel, as it may transfer germs.
Важныя заўвагі:
- Не выкарыстоўвайце абразіўныя ачышчальнікі або растваральнікі.
- Inspect inserts regularly for signs of wear, tear, or damage. Replace immediately if any damage is observed.
7. Выпраўленне непаладак
If you encounter issues while using your Bellababy Flange Inserts, refer to the following common problems and solutions:
- Issue: Inserts do not fit securely in the pump flange.
рашэнне: Ensure you are using Bellababy 19mm Flange Inserts with compatible Bellababy Wearable Pumps BLA8040 or BLA8042. Check that the insert is fully seated and aligned correctly within the larger flange.
- Issue: Discomfort or pain during pumping.
рашэнне: The 19mm size might still be incorrect for your nipple. Consult a lactation professional to confirm your correct flange size. Ensure the insert is clean and free from damage. Check that your nipple is centered and moving freely within the insert tunnel.
- Issue: Reduced milk output.
рашэнне: Incorrect flange sizing can affect milk output. Re-evaluate your flange size. Ensure all pump parts, including the inserts, are assembled correctly and creating a proper seal. Check for any damage to the inserts or other pump components that might affect suction.
8. Тэхнічныя характарыстыкі
| Нумар мадэлі тавару | УСТАЎКА-19 |
| Памеры ўпакоўкі | 4.84 х 4.25 х 3.62 цалі |
| Вага прадмета | 1.44 унцыі |
| Патрабуюцца батарэі | няма |
| ASIN | B0CLG6BDVJ |
9. Гарантыя і падтрымка
Bellababy products are manufactured with quality and care. For specific warranty information regarding your flange inserts, please refer to the warranty details provided with your Bellababy wearable pump or visit the official Bellababy website. For customer support, technical assistance, or to report any issues, please contact Bellababy customer service through their official channels.
Калі ласка, захавайце гэтую інструкцыю для выкарыстання ў будучыні.