1. Уводзіны
This manual provides detailed instructions for the installation, operation, and maintenance of your OREiN 4500LM/30W Motion Sensor Outdoor Flood Light. Please read this manual thoroughly before installation and use to ensure proper function and safety. Keep this manual for future reference.

Image 1: OREiN 4500LM/30W Motion Sensor Outdoor Flood Light, front view with three adjustable light heads and a motion sensor below.
2. Інфармацыя па бяспецы
ПАПЯРЭДЖАННЕ: Risk of electric shock. Disconnect power at the fuse or circuit breaker before installation or servicing. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
- Перад пачаткам усталёўкі пераканайцеся, што электрасілкаванне адключана.
- Use only approved connectors and wiring suitable for outdoor use.
- Не спрабуйце мадыфікаваць прыстасаванне. Любыя мадыфікацыі могуць ануляваць гарантыю і стварыць пагрозу бяспецы.
- Калі ў вас ёсць сумневы адносна якой-небудзь часткі працэсу ўстаноўкі, звярніцеся да кваліфікаванага электрыка.
- This fixture is designed for outdoor use and is IP65 waterproof rated.
3. Змесціва ўпакоўкі
Перад пачаткам усталёўкі пераканайцеся, што ўсе кампаненты наяўныя:
- Свяцільня (1)
- Мантажны кранштэйн (1)
- Шрубы (для мацавання)
- Wire Nuts (for electrical connections)
- Інструкцыя па эксплуатацыі (1)
4. Асаблівасці прадукту
- Высокая яркасць і эфектыўнасць: 4500 Lumens output with 30W power consumption, offering 150LM/W efficiency.
- Adjustable Motion Sensor: 180° wide sensing angle with a detection range up to 50 feet.
- Тры рэжыму працы: TEST Mode, AUTO Mode, and Dusk-to-Dawn (D2D) Mode for versatile lighting control.
- Трывалы і ўстойлівы да надвор'я: IP65 waterproof rating, constructed from polycarbonate material for resistance against rain, dust, snow, and extreme temperatures.
- Гнуткая ўстаноўка: Supports both wall mounting and soffit mounting.
- Рэгуляваныя галоўкі святла: Three light heads can be independently adjusted to direct illumination where needed.
- Каляровая тэмпература: 5000 Kelvin (white light).

Image 2: Illustration demonstrating the IP65 waterproof rating, showing the flood light enduring rain, snow, and wind.

Image 3: Diagram showing the flexible adjustment angles of the three light heads (up to 340° horizontally, 90° vertically) and the motion sensor (up to 270° horizontally, 120° vertically).
5. Настройка і ўстаноўка
This flood light is hardwired and requires connection to your home's electrical system. Professional installation is recommended.
- Выключыць харчаванне: Before starting, ensure the power to the installation area is turned off at the circuit breaker.
- Бяспечны мантажны кранштэйн: Прымацуйце мантажны кранштэйн да размеркавальнай скрынкі з дапамогай прадугледжаных шруб. Пераканайцеся, што ён надзейна замацаваны.
- Падключыце правады: Connect the household wiring to the light fixture's wires using the provided wire nuts. Typically, black to black (live), white to white (neutral), and green/bare copper to green (ground).
- Замацуеце свяцільня: Mount the light fixture onto the mounting bracket, ensuring a tight and secure fit.
- Insert Waterproof Plug: Ensure any necessary waterproof plugs are properly inserted to maintain the IP65 rating.
- Адрэгулюйце галоўкі святла: Position the three light heads to cover the desired illumination area.

Image 4: Step-by-step diagram illustrating the hardwired installation process, including securing the mounting bracket, connecting wires, and attaching the light fixture.

Малюнак 5: Прыкладamples of the flood light installed in both wall-mounted and soffit-mounted configurations.
6. Інструкцыя па эксплуатацыі
The OREiN flood light features an adjustable motion sensor with three distinct operating modes:

Малюнак 6: Крупны план view of the motion sensor controls, showing dials for TIME (1/5/10 minutes), SENSITIVITY (10ft/20ft/30ft/Max 50ft), and a switch for MODE (TEST/AUTO/D2D).
Выбар рэжыму:
- Тэставы рэжым: The light turns on for a fixed 5-second duration when motion is detected, regardless of ambient light. This mode is used for testing the sensor's coverage area during installation.
- Аўтаматычны рэжым: The light activates only at night when motion is detected. The duration the light stays on and the sensitivity of the sensor can be adjusted.
- D2D (Dusk-to-Dawn) Mode: The light automatically turns on at dusk and turns off at dawn, providing continuous illumination throughout the night. Motion sensing is not active in this mode.

Image 7: Visual explanation of the three operating modes: Test Mode (light on for 5s with motion), D2D Mode (light on all night), and Auto Mode (light on at night with motion for adjustable time).
Adjusting Settings (AUTO Mode):
- TIME Dial: Adjusts how long the light stays on after motion is detected. Options typically include 1, 5, or 10 minutes.
- SENSITIVITY Dial: Adjusts the detection range of the motion sensor. Options typically include 10ft, 20ft, 30ft, or Max (up to 50ft). A higher sensitivity setting means a longer detection distance.
7. Тэхнічнае абслугоўванне
Рэгулярнае абслугоўванне забяспечвае аптымальную прадукцыйнасць і даўгавечнасць вашага пражэктара.
- Уборка: Periodically clean the light fixture and motion sensor lens with a soft, damp тканіна. Не выкарыстоўвайце абразіўныя ачышчальнікі або растваральнікі.
- агляд: Regularly inspect the wiring and mounting for any signs of wear, damage, or loosening. Address any issues promptly.
- Без замены лямпачкі: This LED fixture does not require bulb replacement. The integrated LEDs are designed for long-term use.
8. Выпраўленне непаладак
If you encounter issues with your OREiN flood light, refer to the following common problems and solutions:
- Святло не гарыць:
- Ensure power is supplied to the fixture and the circuit breaker is not tripped.
- Check the mode setting. In AUTO mode, it will only activate at night. In D2D mode, it will only activate at dusk.
- Verify the motion sensor is not obstructed.
- Light stays on continuously:
- If in D2D mode, this is normal operation.
- If in AUTO mode, reduce the SENSITIVITY setting. Environmental factors like moving branches or passing vehicles can trigger the sensor.
- Ensure the TIME dial is set correctly.
- Motion sensor is not detecting:
- Increase the SENSITIVITY setting.
- Пераканайцеся, што лінза датчыка чыстая і не засмечаная.
- Verify the sensor is aimed correctly towards the desired detection area.
9. Тэхнічныя характарыстыкі
| Асаблівасць | Спецыфікацыя |
|---|---|
| Марка | OREiN |
| Назва мадэлі | OL3600354 |
| Памеры прадукту | 7.6 см Д х 8 см Ш х 6 см В |
| Вага прадмета | 1.92 фунта |
| Яркасць | 4500 люмен |
| Ватtage | 30 ват |
| Каляровая тэмпература | 5000 кельвінаў (белае святло) |
| Узровень воданепранікальнасці | Воданепранікальны IP65 |
| Motion Sensing Angle | 180° |
| Адлегласць зандзіравання руху | Да 50 футаў |
| Крыніца харчавання | AC/DC (Hardwired) |
| Матэрыял | Акрыланітрылбутадыенстырол (АБС) |
| Тып ўстаноўкі | Насценнае і потолочное мацаванне |
| тtage | 120 вольт |
| Уключаныя кампаненты | Light Fixture, Mounting Bracket, Screws, Wire Nuts, Instruction Manual |

Image 8: Comparison table showing specifications for different OREiN 3-head flood light models, including the 4500LM/30W version.
10. Гарантыя
This OREiN flood light is covered by a Гарантыя 24 месяцаў з даты пакупкі. Калі ласка, захавайце пацвярджэнне пакупкі для прэтэнзій па гарантыі. Гарантыя распаўсюджваецца на дэфекты матэрыялаў і вырабу пры нармальным выкарыстанні.
11. Падтрымка
For any questions, technical assistance, or warranty inquiries, please contact OREiN customer support:
- Падтрымка па тэлефоне: 1-844-506-1530 (available during working hours)
- Інтэрнэт-даведка: 7 days a week, 24 hours a day. Please refer to the official OREiN website or contact through the Amazon platform for online support options.