VEVOR LX-33629A-1

VEVOR 30 lbs Refrigerant Recovery Tank

Model: LX-33629A-1

Кіраўніцтва па эксплуатацыі

Уводзіны

This manual provides essential instructions for the safe and efficient operation of your VEVOR 30 lbs Refrigerant Recovery Tank, Model LX-33629A-1. Please read this manual thoroughly before use to ensure proper handling and to prevent injury or damage.

The VEVOR refrigerant recovery tank is designed for the safe collection and storage of various refrigerants, including R134A, R-22, R-12, R410A, R404A, R502, R1234YF, and R32. It features a robust HP295 steel construction, a float switch for automatic shut-off, and a pressure relief valve for enhanced safety.

Safety Warning: Always wear appropriate personal protective equipment (PPE) such as safety glasses and gloves when handling refrigerants. Ensure proper ventilation in your work area. Refer to local regulations for refrigerant handling and disposal.

Прадукт скончаныview

The VEVOR Refrigerant Recovery Tank is engineered for durability and ease of use. Key features include:

  • Аўтаматычнае адключэнне: Equipped with a float switch, the tank automatically stops recovery when it reaches 80% capacity, preventing overfilling.
  • Шырокая сумяшчальнасць: Includes 1/4" SAE to 1/2" ACME brass adapters, allowing connection to most standard hoses and systems.
  • Функцыі бяспекі: Features an explosion-proof design with a brass Y-valve for effective liquid and vapor recovery, and a pressure relief valve that activates if internal pressure exceeds safe limits.
  • Трывалая канструкцыя: Made from 0.1-inch (2.54 mm) thick HP295 steel with a glossy powder coating for long-term resistance to wear and corrosion.
  • Nitrogen Pre-fill: Contains a trace amount of nitrogen to help prevent internal corrosion.
VEVOR Refrigerant Recovery Tank connected to a recovery machine, showing 'Recovery Tank with Nitrogen' and 'Automatic power off' features.

Image: The VEVOR Refrigerant Recovery Tank connected to a recovery machine, highlighting its nitrogen pre-fill for corrosion prevention and automatic power-off feature at 80% capacity.

Close-up of the VEVOR Recovery Tank's brass Y-valve, indicating Vapor Valve, Liquid Valve, and 1/4 inch SAE Fitting.

Выява: Падрабязны view of the tank's brass Y-valve, clearly labeling the Vapor Valve (red), Liquid Valve (blue), and the 1/4" SAE Fitting for secure connections.

VEVOR Recovery Tank with an inset showing the explosion-proof pressure relief valve, emphasizing high pressure resistance.

Image: The recovery tank with an inset highlighting the explosion-proof pressure relief valve, designed for high-pressure resistance and safe operation.

Папярочны разрэз view of the VEVOR Recovery Tank showing HP295 steel and powder coating for rust resistance.

Image: A cross-sectional diagram illustrating the tank's heavy-duty construction, featuring 0.1-inch thick HP295 steel and a protective powder coating for rust resistance and long-term durability.

VEVOR Recovery Tank with 1/4 inch SAE to 1/2 inch ACME brass adapters, showing compatibility with various refrigerants and hoses.

Image: The recovery tank displayed with the included 1/4" SAE to 1/2" ACME brass adapters, demonstrating its compatibility with various refrigerants and hoses for diverse applications.

Тэхнічныя характарыстыкі

Асаблівасць Дэталь
Нумар мадэлі LX-33629A-1
Ёмістасць 30 фунтаў (13.6 кг)
Працоўны ціск 400 psi / 2.7 Мпа
Тэставы ціск 800 psi / 5.5 Мпа
Матэрыял HP295 Steel
Памеры вырабу (дыяметр х вышыня) Φ 9 x 15.4 inches (Φ 240 x 390 mm)
Вага нета 15.4 фунтаў (7 кг)
Дыяпазон тэмператур -10 да 50 °C
Уключаныя кампаненты 1 Refrigerant Recovery Tank, 2 x 1/4" SAE to 1/2" ACME Brass Adapters
Diagram showing the dimensions of the VEVOR Recovery Tank: 15.4 inches (39 cm) height and 9 inches (24 cm) diameter.

Image: A visual representation of the tank's dimensions, indicating a height of 15.4 inches (39 cm) and a diameter of 9 inches (24 cm), along with a summary of key specifications.

Настройка

Before connecting the recovery tank, ensure all components are clean and free from damage. Follow these steps for initial setup:

  1. Inspect the tank for any visible damage or leaks. Do not use if damaged.
  2. Ensure the vapor (red) and liquid (blue) valves on the tank are in the closed position.
  3. Connect the appropriate hose from your refrigerant recovery machine to the tank's vapor port (red valve) and liquid port (blue valve). Use the provided 1/4" SAE to 1/2" ACME brass adapters if your hoses require them.
  4. Connect the other end of the recovery machine to the system from which refrigerant will be recovered (e.g., AC unit, refrigerator).
  5. Verify all connections are secure and leak-free before proceeding.
A person connecting the VEVOR Recovery Tank to a refrigerant recovery machine with gauges and hoses.

Image: A user connecting the VEVOR Refrigerant Recovery Tank to a recovery machine, illustrating the typical setup for refrigerant transfer.

Інструкцыя па эксплуатацыі

Follow these steps for safe and effective refrigerant recovery:

  1. Ensure the recovery tank is placed on a stable, level surface in a well-ventilated area.
  2. Slowly open the vapor (red) and liquid (blue) valves on the recovery tank.
  3. Initiate the recovery process on your refrigerant recovery machine according to its specific operating instructions.
  4. Monitor the recovery process. The tank's internal float switch will automatically stop the recovery when the tank reaches approximately 80% of its capacity (around 24 lbs or 10.88 kg) to prevent overfilling and ensure safety.
  5. Once recovery is complete or the tank automatically shuts off, immediately close the vapor and liquid valves on the tank.
  6. Carefully disconnect the hoses from the tank and the recovery machine. Be aware of any residual pressure.
  7. Store the tank in a cool, dry, and well-ventilated area, away from direct sunlight and heat sources.

Тэхнічнае абслугоўванне

Regular maintenance ensures the longevity and safe operation of your recovery tank.

  • Уборка: Keep the exterior of the tank clean. Wipe with a damp cloth as needed. Do not use abrasive cleaners or solvents that could damage the powder coating.
  • агляд: Periodically inspect the tank for signs of corrosion, dents, or other physical damage. Check the valves and connections for wear, leaks, or proper sealing. Replace any worn or damaged components immediately.
  • захоўванне: Store the tank upright in a cool, dry place away from direct sunlight, heat sources, and corrosive materials. Ensure all valves are tightly closed during storage.
  • Сыход за клапанам: Ensure the valves operate smoothly. Do not overtighten connections, as this can damage the valve threads or seals.

Ліквідацыю непаладак

выпуск Магчымая прычына Рашэнне
Tank not filling or slow recovery. Valves on the tank are not fully open. Ensure both vapor and liquid valves are completely open.
Hoses are kinked or blocked. Check hoses for obstructions or kinks.
Recovery machine malfunction. Refer to your recovery machine's manual for troubleshooting.
Automatic shut-off activates prematurely. Tank is near 80% capacity. This is normal operation. The tank is designed to stop at 80% capacity. Use another tank if more capacity is needed.
Няспраўнасць паплаўковага выключальніка. Contact VEVOR customer support for assistance.
Leaks detected at connections. Loose connections or damaged O-rings/gaskets. Tighten all connections. Inspect and replace any damaged O-rings or gaskets.

Гарантыя і падтрымка

For warranty information, technical support, or replacement parts, please contact VEVOR customer service. Refer to your purchase documentation for specific warranty terms and contact details.

You can typically find support information on the official VEVOR website or through your retailer. Always provide your model number (LX-33629A-1) when seeking support.

© 2026 VEVOR. Усе правы абаронены.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.