ASD A-BLD-HM08D

ASD Battery Back-Up Kit 8W Instruction Manual

Model: A-BLD-HM08D

1. Уводзіны

Thank you for choosing the ASD Battery Back-Up Kit 8W. This emergency battery back-up unit is designed to provide reliable power to compatible LED commercial downlights (such as ASD-CDL7, CD-P, CD-T) for 90 minutes during a power outage. It features a durable lithium-ion battery, multi-protection functions, and an automatic self-testing capability to ensure continuous readiness. This manual provides essential information for safe installation, operation, and maintenance of your device.

ASD Battery Back-Up Kit 8W and test switch

Image 1.1: The ASD Battery Back-Up Kit 8W, showing the emergency LED driver and the charging indicator/test switch.

2. Інфармацыя па бяспецы

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or other hazards. Keep this manual for future reference.

  • ПАПЯРЭДЖАННЕ: Рызыка паражэння электрычным токам. Адключыце сілкаванне перад устаноўкай або абслугоўваннем.
  • Installation should be performed by a qualified electrician in accordance with the National Electrical Code (NEC) and local code requirements.
  • Do not use this device with dimmers unless explicitly stated as compatible.
  • Пераканайцеся, што ўсе злучэнні надзейныя і належным чынам ізаляваны.
  • Do not modify or disassemble the unit. There are no user-serviceable parts inside.
  • This product is damp-rated. Do not expose to direct water spray or submersion.
  • Operating temperature range must be observed to ensure proper function and battery life.

3. Асаблівасці прадукту

The ASD Battery Back-Up Kit 8W is engineered with several key features to provide reliable emergency lighting:

  • Аварыйная аперацыя: Provides 90 minutes of constant output power to the connected LED fixture during a power outage.
  • Трывалы акумулятар: Equipped with a long-lasting lithium-ion battery designed for 5000 cycles of standard charge and discharge.
  • Multi-Protection Functions: Includes overcharge protection, over-discharge protection, short circuit protection, and over-temperature protection for enhanced safety and durability.
  • Self-Checking Option: Automatically performs a monthly self-test (30 seconds duration) and an annual self-test (90 minutes duration) to verify emergency function and battery capacity.
  • Індыкатар рэжыму: A clear indicator allows users to easily see whether the unit is operating in back-up mode or AC mode.
  • Лёгкая ўстаноўка: Designed for direct connection to the AC input of the fixture, simplifying the installation process.
  • Сертыфікавана UL: Забяспечвае выкананне нормаў бяспекі.
Features of ASD Battery Back-Up Kit

Image 3.1: Visual representation of key features including 90 minutes emergency mode, indicator, self-testing, and multi-protection.

4. Тэхнічныя характарыстыкі

Detailed technical specifications for the ASD Battery Back-Up Kit 8W:

Спецыфікацыя Каштоўнасць
Марка РАС
Нумар мадэлі A-BLD-HM08D
Ватtage 8W
Працягласць экстранай сітуацыі 90 хвілін
Акумулятарныя цыклы 5000 cycles (charge/discharge)
тtage 120-347 Вольт
Памеры прадукту 10.43 х 1.97 х 0.95 цалі
Вага прадмета 2 фунта
Матэрыял Жалеза
Сертыфікаты Сертыфікавана UL
Рэйтынг месцазнаходжання Damp Ацэнены
Памеры і характарыстыкі вырабаў

Image 4.1: Detailed product dimensions and key specifications.

5. Ўстаноўка

Follow these steps for proper installation of the battery back-up kit. Ensure power is disconnected before beginning.

  1. Secure the Battery Back-Up Kit: Securely mount the battery back-up unit to the ceiling structure or within an accessible junction box, ensuring it is stable and properly supported.
  2. Падключыце правады: Refer to the electrical diagram below for wiring connections. Connect the battery back-up unit to the fixture and the main power supply. Ensure all connections are tight and insulated.
  3. Install Test Switch: Connect the test switch to the battery back-up unit and affix it in a visible and accessible location on the surface, typically a wall plate.
  4. Аднавіць сілу: Once all connections are verified and secure, restore power to the circuit. The unit will begin charging.
Installation steps for battery back-up kit

Image 5.1: Visual guide for securing the unit and connecting wires.

Electrical wiring diagram for battery back-up kit

Image 5.2: Detailed electrical wiring diagram for connecting the battery back-up, fixture, and driver.

6. Аперацыя

Once installed and powered, the ASD Battery Back-Up Kit operates automatically:

  • Normal Operation (AC Mode): When AC power is present, the unit charges its internal battery and the connected LED fixture operates normally. The mode indicator will show the AC mode status (e.g., green light).
  • Emergency Operation (Back-Up Mode): У выпадку ўлады унtage, the unit automatically switches to battery back-up mode, providing emergency power to the connected fixture for 90 minutes. The mode indicator will change to reflect back-up mode (e.g., red light).
  • Самаправерка:
    • Штомесячная самаправерка: The battery automatically performs a 30-second self-test every 30 days to check if the emergency function is normal.
    • Annual Self-Test: An annual 90-minute self-test is performed to check the capacity of the battery pack.
  • Тэст уручную: Press the test button on the charging indicator/test switch to manually initiate a brief test of the emergency function.
Back-up or AC mode indicator

Image 6.1: The charging indicator/test switch showing the operational status.

Regular self-testing feature

Image 6.2: Illustration of the regular self-testing function.

7. Тэхнічнае абслугоўванне

The ASD Battery Back-Up Kit requires minimal maintenance due to its self-testing capabilities. However, regular visual inspections are recommended:

  • Візуальны агляд: Periodically check the unit and wiring for any signs of damage, wear, or loose connections.
  • Праверка індыкатара: Ensure the mode indicator light is functioning correctly and displays the appropriate status (AC mode or back-up mode during a test).
  • Уборка: Пры неабходнасці акуратна працярыце знешнія паверхні прылады сухой мяккай тканінай. Не выкарыстоўвайце абразіўныя ачышчальнікі або растваральнікі.
  • Замена батарэі: The battery is designed for long life. If the unit consistently fails self-tests or does not provide the rated emergency duration, the unit may need replacement. Contact customer support for assistance.

8. Выпраўленне непаладак

If you encounter issues with your ASD Battery Back-Up Kit, refer to the following common problems and solutions:

праблема Магчымая прычына Рашэнне
Unit does not charge / Indicator light off No AC power; Loose wiring; Faulty unit. Check circuit breaker; Verify all wiring connections; Contact customer support if power is present and connections are secure.
Fixture does not illuminate in emergency mode Battery not charged; Incompatible fixture; Faulty unit. Allow 24 hours for initial charge; Ensure fixture is compatible (0/1-10V dimming, up to 150W); Perform manual test; Contact customer support.
Emergency duration is less than 90 minutes Battery degradation; High ambient temperature. Ensure unit is within recommended operating temperature; Unit may need replacement if battery is degraded.
Self-test fails Battery issue; Internal fault. Ensure unit has been fully charged; Contact customer support for diagnosis and potential replacement.

9. Гарантыя і падтрымка

ASD забяспечвае 5-гадовая абмежаваная гарантыя for the Battery Back-Up Kit 8W, guaranteeing top quality products and safety. This warranty covers defects in materials and workmanship under normal use and service.

For technical support, warranty claims, or any questions regarding your product, please contact ASD customer support. Our team is committed to responding to your concerns within 24 hours.

Кантактная інфармацыя: Калі ласка, звярніцеся да вытворцы webна сайце або ўпакоўцы прадукту, каб знайсці найбольш актуальную кантактную інфармацыю.

© 2024 ASD Lighting Corp. All rights reserved.