1. Уводзіны
The EAGLENOS Blood Lactate Test Strips are designed for the quantitative determination of lactate concentration in fresh capillary whole blood from fingertips and venous whole blood. These strips are intended for use with a compatible lactate meter (not included) for athletic performance monitoring and other relevant applications. This package contains 50 replacement test strips.
2. Змест прадукту
- 50 x EAGLENOS Blood Lactate Test Strips (Model: EN300R1)
Заўвага: The lactate meter and batteries are not included in this package. These strips are replacements for an existing lactate monitoring system.

Figure 1: Packaging for EAGLENOS Blood Lactate Test Strips, 50-Pack. The box indicates 'EAGLENOS Blood Lactate Test Strips [EN300R1]' and states their use for determining lactate concentration in blood.
3. Інфармацыя па бяспецы і меры засцярогі
- Для in vitro diagnostic use only. Do not ingest.
- Захоўваць у месцах, недаступных дзецям.
- Do not use expired test strips. Check the expiration date on the vial.
- Захоўвайце тэст-палоскі ў арыгінальным флаконе з шчыльна зачыненай вечкам. Не пералівайце палоскі ў іншы кантэйнер.
- Avoid direct sunlight, heat, and moisture.
- Dispose of used test strips and lancets (if applicable) according to local regulations for biohazardous waste.
- Заявы адносна дыетычных дабавак не былі ацэнены FDA і не прызначаны для дыягностыкі, лячэння або прафілактыкі якіх-небудзь захворванняў або стану здароўя.
4. Захоўванне і апрацоўка
- Store the test strip vial at temperatures between 50 °F to 104 °F (10 °C to 40 °C).
- Не захоўваць у халадзільніку і не замарожваць.
- Выкарыстоўвайце тэст -палоску адразу пасля выдалення яе з флакона.
- Ensure hands are clean and dry before handling test strips.
5. Operating Instructions: Using the Test Strips
These instructions describe the general procedure for using EAGLENOS Blood Lactate Test Strips. Always refer to your specific lactate meter's user manual for detailed instructions on meter operation.
5.1. Падрыхтоўка
- Ensure your lactate meter is clean, functional, and has sufficient battery power.
- Старанна вымыйце рукі з мылам і цёплай вадой, затым цалкам высушыце іх.
- Prepare a lancing device and a new sterile lancet (not included).
- Remove one test strip from the vial and immediately close the cap tightly.
- Insert the test strip into the meter as directed by your meter's manual. The meter should turn on automatically or prompt you to apply blood.
5.2. Performing the Test
- Prick your fingertip (or other approved site) with the lancing device to obtain a blood sampле.
- Gently squeeze your finger to form a round drop of blood.
- Touch the tip of the test strip to the blood drop. The blood will be drawn into the strip by capillary action. Do not apply blood to the top of the strip.

Figure 2: An individual EAGLENOS Blood Lactate Test Strip. The strip features a sample application area at one end and contact pads at the other for insertion into a compatible meter.
5.3. Вынікі чытання
- Hold the strip in place until the meter indicates that enough blood has been applied.
- The meter will begin a countdown. The response time for these strips is approximately 10 seconds.
- After the countdown, your lactate result will be displayed on the meter's screen.
- Remove the used test strip and dispose of it properly.
6. Выпраўленне непаладак
If your lactate meter displays specific messages, refer to the following common indicators:
- "LO" Message: This indicates that the measured lactate value is too low, below the meter's detectable range (e.g., less than 0.5 mmol/L).
- "HI" Message: This indicates that the measured lactate value is too high, above the meter's detectable range (e.g., greater than 28 mmol/L).
For other error messages or persistent issues, consult your lactate meter's user manual or contact customer support.
7. Тэхнічныя характарыстыкі
| Назва прадукту | EAGLENOS Blood Lactate Test Strips |
| Нумар мадэлі | EN300R1 |
| Колькасць | Па 50 штукі ў пакаванні |
| Дыяпазон вымярэнняў | 0.5 ~ 28 ммоль/л |
| Час водгуку | 10 секунд |
| Працоўная тэмпература | Ад 50 °F да 104 °F (ад 10 °C да 40 °C) |
| Sampле Тып | Капілярная суцэльная кроў, вянозная суцэльная кроў |
8. Падтрымка кліентаў
For any questions, concerns, or assistance with your EAGLENOS Blood Lactate Test Strips, please contact our customer support team. We are committed to responding to your inquiries within 24 hours.
Спосаб сувязі: Please reach out via email through the Amazon platform.