Elitech PG-30

Elitech PG-30Pro Digital Pressure Gauge User Manual

Model: PG-30 | Brand: Elitech

1. Уводзіны

This manual provides detailed instructions for the proper use and maintenance of the Elitech PG-30Pro Digital Pressure Gauge. This device is designed for accurate pressure measurement in refrigeration and HVAC systems. Please read this manual thoroughly before operation to ensure correct usage and to prevent damage.

Elitech PG-30Pro Digital Pressure Gauge

Figure 1: Elitech PG-30Pro Digital Pressure Gauge. This image displays the front view of the digital pressure gauge, featuring a blue face with a clear LCD screen, power button, 'SET' button, and 'ZERO' button. The 1/8'' NPT connection is visible at the bottom.

2. Асаблівасці прадукту

  • Stable and Reliable Sensor: Utilizes a temperature-compensated pressure sensor, ensuring temperature drift does not exceed ±0.04%FS/℃.
  • LCD Screen & Blue Backlight Display: Features a partitioned display for various measurements, providing direct readings for all parameters. The blue backlight enhances visibility in low-light conditions.
  • Various Refrigerants Options: Includes a built-in PT (Pressure-Temperature) comparison table for 87 common refrigerants, facilitating convenient selection.
  • Нулявая функцыя: Allows for zeroing out any deviation at the zero point to correct the system and ensure accurate measurements.
  • Overload Warning Indications: Displays 'ALARM' on the screen for overload conditions. If the overload is excessively high, 'ALARM' and the backlight will flash simultaneously.
  • Max/Min Value Display and Reset: Records maximum and minimum pressure values, with an option to reset these values.
  • Auto Shut-Off Setting: Features an automatic shut-off function to conserve battery power during periods of inactivity.
  • Adjustable Temperature and Pressure Units: Supports various temperature units (°C / °F) and pressure units (psi, kg/cm², cmHg, bar, kPa, Mpa, kg/cm²).
  • 1/8-inch NPT Fitting: Equipped with a standard 1/8-inch NPT fitting for broad compatibility with various systems.
Elitech PG-30Pro Features Overview

Малюнак 2: Закончанаview of Elitech PG-30Pro features. This graphic highlights key functionalities such as backlight display, Max/Min value, zeroing, refrigerant support, auto shut-off, and adjustable units.

Elitech PG-30Pro Refrigerant Compatibility

Figure 3: Refrigerant compatibility of the Elitech PG-30Pro. This image illustrates the gauge's ability to work with over 90 types of refrigerants, including R12, R22, R134a, R290, R401A, R403A, R740, R744, R601, R143A, R32, R21, and R1234yf.

3. Настройка

3.1 Устаноўка батарэі

  1. Знайдзіце вечка батарэйнага адсека на задняй панэлі прылады.
  2. Remove the cover by twisting or sliding it according to the markings.
  3. Устаўце дзве (2) батарэйкі тыпу AAA, сочачы за правільнай палярнасцю (+/-), як паказана ўнутры адсека.
  4. Надзейна заменіце крышку батарэйнага адсека.

3.2 Пачатковае падключэнне

  1. Ensure the system to which the gauge will be connected is depressurized or isolated.
  2. Carefully thread the 1/8'' NPT fitting of the digital pressure gauge onto the appropriate port of your HVAC or refrigeration system.
  3. Tighten the connection firmly by hand, then use a wrench for a final snug turn to prevent leaks. Do not overtighten.
Elitech PG-30Pro 1/8-inch NPT Fitting

Figure 4: Dimensions and 1/8-inch NPT fitting. This image shows the physical dimensions of the gauge and highlights the 1/8-inch NPT threaded connection for system integration.

4. Інструкцыя па эксплуатацыі

4.1 Уключэнне/выключэнне сілкавання

  • Каб уключыць прыладу, націсніце Магутнасць button (⏻) located at the top of the gauge.
  • Каб выключыць прыладу, націсніце і ўтрымлівайце Магутнасць button (⏻) for approximately 3 seconds until the display turns off.

4.2 Zero Function

The zero function is used to correct any minor deviations at the zero pressure point before taking a measurement.

  • Ensure the gauge is disconnected from any pressure source and is at ambient atmospheric pressure.
  • Націсніце НУЛЬ button (▶) located at the bottom right of the gauge. The display should show 0.000 psi (or selected pressure unit).
Elitech PG-30Pro Zeroing Function

Figure 5: Zeroing function button. This image highlights the 'ZERO' button on the gauge, indicating its use for resetting the pressure reading to zero.

4.3 Changing Units (Pressure/Temperature)

To cycle through available pressure and temperature units:

  • Націсніце НАБОР button (◀) to enter the unit selection mode.
  • Выкарыстоўвайце НУЛЬ button (▶) to cycle through the available pressure units (psi, kg/cm², cmHg, bar, kPa, Mpa, kg/cm²).
  • Націсніце НАБОР button (◀) again to switch to temperature unit selection.
  • Выкарыстоўвайце НУЛЬ button (▶) to select between °C and °F.
  • Націсніце НАБОР button (◀) to confirm your selection and exit unit setting mode.
Elitech PG-30Pro Adjustable Units

Figure 6: Adjustable temperature and pressure units. This graphic illustrates the various units available for both temperature (°C / °F) and pressure (psi, kg/cm², cmHg, bar, kPa, Mpa, kg/cm²).

4.4 Selecting Refrigerants

The gauge has a built-in database of refrigerants for PT comparison.

  • While in normal measurement mode, press and hold the НАБОР button (◀) to enter refrigerant selection mode.
  • Выкарыстоўвайце НУЛЬ button (▶) to scroll through the list of available refrigerants.
  • Once the desired refrigerant is displayed, press the НАБОР button (◀) to confirm your selection and return to measurement mode.

4.5 Вымярэнні паказанняў

Once connected and powered on, the gauge will display the current pressure and corresponding saturation temperature for the selected refrigerant on its LCD screen.

4.6 Max/Min Value Display and Reset

каб view the recorded maximum and minimum pressure values:

  • Каротка націсніце Магутнасць button (⏻) during operation to cycle through current, maximum, and minimum pressure readings.
  • To reset the recorded Max/Min values, press and hold the НУЛЬ button (▶) while the Max/Min values are displayed.
Elitech PG-30Pro Max/Min Value Display and Reset

Figure 7: Max/Min value display and reset. This image illustrates how the power button is used to cycle through readings and the zero button to reset recorded maximum and minimum values.

4.7 Auto Shut-Off Setting

The gauge features an adjustable auto shut-off time to conserve battery life.

  • To adjust the auto shut-off time, press and hold the НАБОР button (◀) until the auto shut-off setting appears.
  • Выкарыстоўвайце НУЛЬ button (▶) to cycle through the available time options (e.g., 10 minutes, 20 minutes, Off).
  • Націсніце НАБОР button (◀) to confirm your selection.
Elitech PG-30Pro Auto Shut-Off Setting

Figure 8: Auto shut-off setting. This image highlights the 'SET' button, used for configuring the automatic power-off duration to save battery life.

5. Тэхнічнае абслугоўванне

5.1 Ачыстка

  • Wipe the exterior of the gauge with a soft, damp тканіна. Не выкарыстоўвайце абразіўныя ачышчальнікі або растваральнікі.
  • Ensure no moisture enters the sensor port or battery compartment.

5.2 Замена батарэі

  • Замяніце батарэйкі, калі на дысплеі з'явіцца індыкатар нізкага зараду батарэй.
  • Выканайце дзеянні па ўсталёўцы акумулятара, апісаныя ў раздзеле 3.1.
  • Утылізуйце выкарыстаныя батарэі ў адпаведнасці з мясцовымі правіламі.

5.3 Захоўванне

  • Store the gauge in a dry, cool place away from direct sunlight and extreme temperatures.
  • Пры працяглым захоўванні выміце батарэйкі, каб прадухіліць уцечку.

6. Выпраўленне непаладак

праблемаМагчымая прычынаРашэнне
Gauge does not power onРазраджаныя або няправільна ўсталяваныя батарэіЗамяніце батарэйкі, сачыце за правільнай палярнасцю.
Недакладныя паказанні ціскуGauge not zeroed; Sensor contamination; Incorrect unit selectedPerform zero function; Clean sensor port if accessible; Verify selected pressure unit.
Display shows 'ALARM' or flashesPressure overloadImmediately disconnect from pressure source. The gauge is operating beyond its specified range.
Падсвятленне не працуеLow battery; Backlight setting offReplace batteries; Check if backlight can be toggled (refer to operating instructions).

7. Тэхнічныя характарыстыкі

СпецыфікацыяДэталь
Нумар мадэліПГ-30
Дыяпазон ціску-14.5 да 500 PSI
Тып злучэння1/8'' NPT
Тэмпература дрэйфу±0.04%FS/℃
Падтрымка холадагенту87 types built-in
Крыніца харчавання2 х ААА батарэі
МатэрыялПластыкавыя
Памеры прадукту (Д х Ш х У)6.3 х 4.72 х 8.27 цалі
Вага прадмета8.89 унцый

8. Гарантыя і падтрымка

8.1 Інфармацыя аб гарантыі

The Elitech PG-30Pro Digital Pressure Gauge comes with a Гарантыя 12 месяцаў from the date of purchase, covering manufacturing defects and malfunctions under normal use. This warranty does not cover damage caused by misuse, accident, unauthorized modification, or improper installation.

8.2 Тэхнічная падтрымка

For technical assistance, troubleshooting, or warranty claims, please contact Elitech customer support. 24/7 US Technician Support is available via email and phone.

  • электронная пошта: Refer to product packaging or Elitech official webсайт для кантактных дадзеных.
  • тэлефон: Refer to product packaging or Elitech official webсайт для кантактных дадзеных.