PINTECH N1070A
PINTECH N1070A High Voltage Кіраўніцтва па эксплуатацыі дыферэнцыяльнага зонда
Model: N1070A
1. Уводзіны
The PINTECH N1070A is a high-performance differential probe designed for safe and accurate measurement of high voltage signals with an oscilloscope. It features a bandwidth of up to 50MHz and can handle differential voltages up to 7kVp-p, making it suitable for various power electronics and industrial applications. This manual provides essential information for the proper setup, operation, and maintenance of your N1070A differential probe.
2. Інфармацыя па бяспецы
ПАПЯРЭДЖАННЕ: This device measures high voltages. Failure to follow safety precautions can result in serious injury or death. Always adhere to the following safety guidelines:
- Always connect the probe's ground lead to the oscilloscope's ground terminal before connecting the input leads to the circuit under test.
- Ensure the probe is rated for the maximum voltage of the circuit being tested. The N1070A has a maximum differential test voltage of 7kVp-p.
- Не перавышайце максімальны ўваходны аб'ёмtage ratings specified in the technical specifications.
- Inspect the probe, leads, and accessories for any damage before each use. Do not use if any part is damaged.
- Operate the probe only in dry conditions. Avoid exposure to moisture or extreme temperatures.
- Use only the provided adapter or appropriate batteries for power.
- Refer to your oscilloscope's manual for proper connection and operation procedures.
- Абслугоўванне павінна выконвацца толькі кваліфікаваным персаналам.
3. Змесціва ўпакоўкі
Праверце наяўнасць усіх прадметаў у камплекце:
- N1070A Differential Probe x 1
- Адаптар сілкавання x 1
- Probe Hook (Red) x 1
- Probe Hook (Black) x 1
- Інструкцыя па эксплуатацыі x 1

Figure 3.1: Contents of the N1070A package, including the differential probe unit, power adapter, and red and black probe hooks.
4. Настройка
- крыніца харчавання: The N1070A probe can be powered by either the included power adapter or internal batteries (not included).
- To use the adapter, connect it to the probe's power input jack and then to a suitable power outlet.
- To use batteries, open the battery compartment (refer to the diagram on the probe unit) and insert the required batteries, ensuring correct polarity.
- Падключэнне да асцылографа: Connect the BNC cable from the N1070A probe's output to an input channel on your oscilloscope. Ensure the connection is secure.
- Select Attenuation: On the N1070A probe unit, select the desired attenuation ratio (100X or 1000X) using the switch. This setting determines the probe's voltage division ratio.
- Налады асцылографа: Set your oscilloscope's input impedance to 1MΩ. Adjust the vertical scale (Volts/Div) on your oscilloscope according to the selected attenuation ratio. For example, if the probe is set to 100X, a 1V/Div setting on the oscilloscope will represent 100V/Div at the probe tips.
5. Інструкцыя па эксплуатацыі
- Уключэнне: Turn on the N1070A probe using the power switch. The power indicator light should illuminate.
- Нулявое зрушэнне: The probe features a built-in auto-zero function. Allow a few moments for the probe to stabilize after powering on.
- Падключэнне да ланцуга: Carefully connect the red and black input leads of the differential probe to the two points in the circuit where you wish to measure the voltage difference. Use the provided probe hooks for secure connection.
- Observe Waveform: Observe the waveform on your oscilloscope. Adjust the oscilloscope's time base and vertical scale as needed for a clear display.
- Абарона ад перагрузкі: The probe includes overload protection. If the input voltage exceeds the probe's limits, the output may clip or distort. Disconnect immediately and verify the voltagе дыяпазон.
- Выключэнне: After use, disconnect the probe from the circuit under test, then turn off the probe and the oscilloscope.
6. Тэхнічнае абслугоўванне
- Уборка: Clean the probe's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the probe is powered off and disconnected before cleaning.
- захоўванне: Store the probe in a clean, dry environment, away from direct sunlight and extreme temperatures.
- Замена батарэі: If using batteries, replace them when the power indicator dims or the probe malfunctions. Ensure correct polarity during replacement.
- агляд: Regularly inspect the probe body, cables, and connectors for any signs of wear or damage.
7. Выпраўленне непаладак
- Няма харчавання:
- Check if the power adapter is securely connected and functioning.
- Калі карыстаецеся батарэйкамі, пераканайцеся, што яны правільна ўстаўлены і не разраджаны.
- No Signal on Oscilloscope:
- Verify that the BNC cable is securely connected to both the probe and the oscilloscope.
- Ensure the probe is powered on.
- Check the oscilloscope's input channel settings (e.g., input impedance, vertical scale).
- Confirm the probe leads are properly connected to the circuit under test.
- Distorted or Clipped Waveform:
- Уваходны аб'ёмtage may exceed the probe's maximum rating for the selected attenuation. Switch to a higher attenuation ratio (e.g., 1000X) or reduce the input voltage.
- Check the oscilloscope's vertical scale setting; it might be too sensitive.
8. Тэхнічныя характарыстыкі

Figure 8.1: Detailed technical specifications for the N1070A High Voltage Differential Probe.
| Параметр | Каштоўнасць |
|---|---|
| мадэль | N1070A |
| Прапускная здольнасць (-3 дБ) | 100X: DC-40MHz; 1000X: DC-50MHz |
| Attenuation Rate | 1000X/100X |
| Дакладнасць | ±1% |
| Час узрастання | ≥7нс |
| Тэставанне Voltagе (Vp-p) | 100X: 700V; 1000X: 7kV |
| Уваход DC Voltage | 100X: 350V; 1000X: 3.5kV |
| Differential-mode voltagе (Vp-p) | 100X: 350V; 1000X: 3.5kV |
| RMS значэнне | 2450В |
| Агульны рэжым тtage RMS | 2450В |
| Output (into 50kΩ load) | <7 В |
| Зрушэнне (звычайнае) | <± 5 мВ |
| Input Impedance (Between two ends) | 20MΩ//0.5pF |
| Input Impedance (Single-ended to ground) | 10MΩ//1pF |
| Oscilloscope Input Impedance | 1 МОм |
| CMRR (60Hz) | >80 дБ |
| CMRR (100kHz) | >50 дБ |
| Noise RMS (100X) | <100 мВ |
| Noise RMS (1000X) | <500 мВ |
| Вага | 425 г / 0.94 фунта |
| Памеры (ДхШхВ) | 187 х 73 х 41 мм |
| Працоўная тэмпература | 0-50°C |
| Працоўная вільготнасць | 20-75% адноснай вільготнасці |
9. Гарантыя і падтрымка
PINTECH offers a Гарантыя 1 год for the N1070A differential probe from the date of purchase. This warranty covers defects in materials and workmanship under normal use.
For technical support, warranty claims, or any questions regarding the product, please contact PINTECH customer service. Refer to the contact information provided with your purchase documentation or visit the official PINTECH webсайт.
PINTECH is committed to providing professional advice and support to meet your measurement needs.
Звязаныя дакументы - N1070A
![]() |
PINTECH N Series Differential Probe - User Manual and Specifications Comprehensive user manual and technical specifications for the PINTECH N Series Differential Probes, covering models N1008A, N1008B, N1015A, N1000A, N1030A, N1030B, N1070A, N1070APro, N1070B, N1015B, N1100A, N1140A, N1140APro, N2008APro, N2015APro, N2040APro, N2060APro. Learn about features, operation, safety, and specifications. |
![]() |
PINTECH N Series Differential Probes - User Manual and Specifications Comprehensive user manual and technical specifications for PINTECH N Series Differential Probes, covering operation, safety, maintenance, and detailed model comparisons. |
![]() |
PINTECH N1280Apro 差分探头说明书 | 高压示波器探头技术规格与操作指南 PINTECH N1280Apro 高压差分探头用户手册。了解其详细规格、操作说明、安全注意事项以及配件信息,适用于电力测试、研发和维修。 |
![]() |
PINTECH N2060Apro Differential Probe: Instruction Manual and Specifications Comprehensive instruction manual and technical specifications for the PINTECH N2060Apro High Voltage Differential Probe. Learn about its features, operating procedures, safety precautions, specifications, and maintenance. |
![]() |
Pintech N Series High-Precision Active Differential Probes Buyer's Guide A comprehensive guide to Pintech's N Series high-precision active differential probes, detailing their features, specifications, and applications in various electronic testing scenarios. |
![]() |
PINTECH Catalogue: Electronic Measurement & Testing Instruments Explore the comprehensive catalogue from PINTECH, a leading manufacturer of electronic measurement and testing instruments. Discover a wide range of high-precision probes, oscilloscopes, power supplies, and more. |
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.