1. Уводзіны
The Jebao Jecod D series wave pump is an advanced device designed to simulate natural marine ecological environments within aquariums. This high-tech product is specifically engineered for marine life cultivation, enabling the creation of ocean waves that provide a natural living environment for fish and other aquatic organisms. For proper use, please read this instruction manual carefully before installation and operation.
2. Асаблівасці прадукту
- Bluetooth Wireless APP Control: Seamless control via a dedicated mobile application.
- External Drive Controller: The pump itself contains no electronic components, enhancing its lifespan.
- 3D Large Angle Rotation: Allows for adjustable water flow direction to optimize wave patterns.
- Four-Level Silent Motor: Engineered for quiet operation, minimizing disturbance to aquatic life and household environment.
- Compact Size, Powerful Performance: Small footprint without compromising on wave-making capability.
- Master-Slave Pump Wireless Linkage: Multiple pumps can be linked wirelessly for synchronized operation.

3. Тэхнічныя характарыстыкі
3.1 Агульныя тэхнічныя характарыстыкі
- Фірмовае найменне: Джэбао
- матэрыял: Метал
- Fixed Form: Пакласці трубку
- Крыніца харчавання: Зарадзіць
- тtage: 110-240В
- Акумулятар у камплекце: няма
- Хімічнае рэчыва, якое выклікае вялікую заклапочанасць: Няма
- Паходжанне: Кантынентальны Кітай
3.2 Тэхнічныя характарыстыкі мадэлі
The wave pump is available in various models, categorized into DWP, DCW, and DLW series. Users can select the appropriate model(s) based on their specific tank requirements.
- DWP Series Models: DWP-3, DWP-5, DWP-9, DWP-16, DWP-22
- DCW Series Models: DCW-70, DCW-90, DCW-120, DCW-150
- DLW Series Models: DLW-5, DLW-10, DLW-20, DLW-30

3.3 Памеры ўпакоўкі
- Даўжыня: 23 см
- Шырыня: 16 см
- Рост: 13 см
- Вага: 0.879 кг
4. Змесціва ўпакоўкі
Адкрыўшы пакет, вы павінны знайсці наступныя рэчы:
- Разумны кантролер
- Адаптар сілкавання
- Магнітная гара
- Корпус помпы
- Кіраўніцтва па эксплуатацыі
5. Папярэджанні па тэхніцы бяспекі
- To ensure product performance, do not operate the pump without water.
- Install the control box in a waterproof location, taking care to prevent water splashes from reaching it.
- When installing the magnetic suction cup, proceed with caution. It is best to balance and move the rear magnetic cup on the outer wall of the fish tank to secure it, preventing damage to the tank.
- Non-professionals should not attempt to open the control box or adapter to avoid damage.
- Do not allow children or inexperienced individuals to operate the product unsupervised or without safety precautions.
- Пасля ўлады унtage, use a mobile phone connection to ensure accurate operation of the timed mode.
- For first-time use or after prolonged storage, power on the device and operate it continuously for at least one hour to ensure the internal clock battery is charged.
- The actual product may vary slightly from the descriptions.
6. Інструкцыя па ўстаноўцы
6.1 Размяшчэнне помпы
- The pump is generally suitable for all fish tank sizes.
- It can be adsorbed onto fish tank glass with a maximum thickness of 15mm.
- Install the pump body by removing the rear magnetic disc from its bracket. Position the pump body inside the fish tank, then align the external magnetic disc on the outer wall of the tank directly opposite the internal pump body. Due to strong magnetic force, handle with care to avoid pinching fingers.

6.2 Controller and Power Connection
- Select a suitable location for the control box.
- Connect the pump body to the controller using the 3-pin waterproof connection cable.
- Connect the DC plug of the power adapter to the controller.
- Finally, connect the AC line of the power adapter to a power outlet.


7. Controller Operation and Screen Display
7.1 Функцыі кнопак
- "||" Button: Short press to select Master, Slave, or Independent operation. Long press to enter Feeding Mode.
- "MODE/FREQ" Button: Short press to select different function modes. Long press to display frequency, which can be adjusted using the "▲" and "▼" buttons.
- Кнопка харчавання: Short press to turn the device on or off. Long press to reset Bluetooth.
7.2 Wireless Linkage Function
The wave pumps can be linked wirelessly without physical connections for synchronized operation.
- Галоўны кантроль: Short press the "||" button once. The "Master" icon will light up, indicating master control. The master controller can perform all function operations.
- Падпарадкаваны кантроль: Short press the "||" button twice. The "Slave" icon will light up, indicating slave control. The slave controller can only adjust flow; other functions are inactive.
When using two or more wave pumps, set one as the master and the others as slaves. During setup, only the master's functions need to be configured. The slave's functions are determined by the master, and the slave can only adjust flow rate.
7.3 Функцыі рэжыму
- M1: Classic Pulse Mode: Can be used with one or more pumps. Adjust flow rate using the "▲" and "▼" buttons. Long press "MODE/FREQ" to enter frequency adjustment.
- M2: Sine Wave Mode: Can be used with one or more pumps. In this mode, the wave pump's power continuously changes between 30% and 100%, with flow rate changes resembling a sine wave. Long press "MODE/FREQ" to enter frequency adjustment.
- M3: Constant Flow Mode: Can be used with one or more pumps. In this mode, the wave pump maintains a constant flow rate. Adjust flow rate using the "▲" and "▼" buttons.
- M4: Random Wave Mode: Can be used with one or more pumps. This mode operates with an irregular program, where the wave pump's power changes randomly without a fixed pattern.
- M5: Classic Circulation Mode: Can be used with one or more pumps. Adjust flow rate using the "▲" and "▼" buttons. Long press "MODE/FREQ" to enter frequency adjustment.
7.4 Feeding Function
Long press the "||" button. The screen will display "Fd10", and the wave pump will stop operation, allowing the water to remain still for 10 minutes for convenient fish feeding. After 10 minutes, the wave pump will automatically resume its previous mode. If you need to resume operation during the feeding process, long press the "||" button again.
7.5 Функцыя блакіроўкі клавіш
Long press the "MODE/FREQ" buttons simultaneously until a lock icon appears in the upper right corner of the screen, indicating that the keys are locked. To unlock, long press the "MODE/FREQ" buttons again until the lock icon disappears.
8. Bluetooth Control Function
8.1 Спампоўка прыкладання
To download the Jebao Aqua app:
- Для Android: Scan the QR code or search for "Jebao Aqua" on Google Play.
- Для iOS: Пошук "Jebao Aqua" on the App Store.

8.2 User Registration and Password Reset
- Рэгістрацыя: After downloading the app, click "Register Now" on the login screen. Fill in the required information and click "Register Now" to complete. Return to the login screen to log in with your new account.
- Скід пароля: On the login screen, click "Forgot Password". Select your account type, follow the prompts to reset your password, and then return to the main interface to log in.
8.3 Падключэнне прылады
- Уключыце Bluetooth на мабільным тэлефоне.
- Ensure the wave pump controller is powered on.
- In the app, click "Add Bluetooth Device" or the "+" icon in the upper right corner to search for devices.
- Once the device appears in the list, click the Bluetooth icon next to it to successfully add it.
8.4 Controlling the Wave Pump
On the device interface, long press the device icon for 2 seconds to enter the device control interface.
- Кіраванне ўручную: In the device control interface, long press the manual button for 2 seconds to enter manual mode. You can switch between wave modes (Classic Pulse, Sine Wave, Random Wave, Constant Flow) using the left and right buttons at the bottom of the page. Click the central wave mode button to adjust flow (Flow) and frequency (Frequency). The minimum adjustable flow is 30%, and the minimum adjustable frequency is 5. Click "Confirm" to save settings.
- Рэжым кармлення: Set the feeding time and activate the feeding switch. Click "Confirm" to apply. During feeding, the wave pump will pause operation.
- Рэжым сінхранізацыі: In the device control interface, long press the timing icon for about 2 seconds to enter the timing mode settings. Double-click the blank area of the circular ring to add a timed period or use the switch button to automatically add a timed period. Select the wave mode and set parameters in the pop-up window. Adjust the start and end times by dragging the slider or directly modifying them. Click "Done" to save the schedule. To delete a scheduled period, click "Delete". After setting, return to the main page and click the timing icon to activate timing mode.
8.5 Grouping Wave Pumps
Click the "+" icon in the upper right corner to select "Add Group". Select the devices you wish to add to the group and click "Next". Choose the corresponding aquarium or click "+" to customize an aquarium name. Enter the group name and complete the addition.
Long press the group icon for two seconds to enter the group page. Clicking "Settings" on the group page will lead to the group control page, which operates similarly to single pump control. (Note: Grouping does not support linkage settings.)
To add or delete devices within a group (minimum two devices), click the settings icon in the upper right corner.
9. Pump Management
- The factory default time of the device may be inaccurate. For the first use of timed mode, it may be necessary to calibrate the time settings (click "Set Time").
- Users can also change the name of the pump for easier management.
- The current pump can be deleted from the app.
10. Тэхнічнае абслугоўванне
- Regularly clean the wave pump to ensure its effective operation.
- If water gets on the surface of the control box, wipe it dry with a clean cloth to prevent water from entering the control box.
- To clean debris from the pump body, rotate the front net clockwise to lock and counter-clockwise to open.
- Wipe the impeller blades with a soft cloth and clean the pump body with water.
- This product is intended for indoor use only. The control box and adapter must not be allowed to fall into water to prevent unnecessary damage.
11. Выпраўленне непаладак
| праблема | Error Code/Hint | Рашэнне | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Перагрузка па току кантролера | ER01 | Check for short circuits or abnormalities in the controller. | |||||||||||
| Перагрэў кантролера | ER02 | Ensure the controller is not exposed to direct sunlight or high temperatures. | |||||||||||
| Застою помпы | ER04 | Check if the pump impeller is jammed by foreign objects or if wiring is incorrect. Regularly clean the impeller. | |||||||||||
| Controller Overvoltagе/Падвыпtage | ER05 | Праверце ўвод voltage. Use a compliant power adapter. | |||||||||||
| Збой злучэння Bluetooth |
Звязаныя дакументы - DLW/DWP Series Bluetooth Wave Pump
Ask a question about this manualAsk about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it. |





