1. Уводзіны
This manual provides essential information for the safe and efficient use of the Legrand Emdx3 Three-Phase Energy Meter, Model 412043. This device is designed for accurate measurement of electrical energy in three-phase systems, compliant with MID (Measuring Instruments Directive) standards, making it suitable for billing applications. Please read this manual thoroughly before installation and operation.
2. Інструкцыі па тэхніцы бяспекі
WARNING: Electrical shock hazard. Installation and maintenance must be performed by qualified personnel only.
- Заўсёды адключайце харчаванне перад устаноўкай або абслугоўваннем прылады.
- Пераканайцеся, што выконваюцца ўсе мясцовыя і нацыянальныя электрычныя нормы.
- Не выкарыстоўвайце прыладу, калі яна выглядае пашкоджанай.
- Трымайце прыладу далей ад вільгаці і экстрэмальных тэмператур.
- Выкарыстоўвайце адпаведныя сродкі індывідуальнай абароны (СІА) падчас усталёўкі.
3. Прадукт скончыўсяview
The Legrand Emdx3 Three-Phase Energy Meter (Model 412043) is a robust device for monitoring energy consumption. It is designed for use with external current transformers (P/Ti 5A) to measure energy in industrial and commercial three-phase electrical installations. Its MID certification ensures accuracy and reliability for revenue metering.

Малюнак 1: Спераду view of the Legrand Emdx3 Three-Phase Energy Meter. This image shows the display, control buttons, and general housing of the energy meter.
4. Настройка і ўстаноўка
Installation of the Legrand Emdx3 energy meter requires expertise in electrical systems. It must be installed by a qualified electrician in accordance with the provided wiring diagrams and local regulations.
4.1 Мантаж
The meter is typically mounted on a DIN rail within an electrical enclosure. Ensure adequate ventilation and clearance around the device.
4.2 Электрычныя злучэнні
Падключыце тtage inputs and current transformer (CT) secondary wires (5A) to the designated terminals on the meter. Pay close attention to phase sequence and polarity for accurate measurements. Refer to the detailed wiring diagram supplied with the product packaging for specific terminal assignments.
- тtagэлектронныя злучэнні: Connect the three-phase voltage lines (L1, L2, L3) and neutral (N) to the meter's voltagе тэрміналы.
- Current Transformer Connections: Connect the secondary outputs of the external current transformers (P/Ti 5A) to the corresponding current input terminals on the meter. Ensure correct phasing.
- Auxiliary Power (if applicable): Some models may require separate auxiliary power. Consult the wiring diagram.
CAUTION: Incorrect wiring can damage the meter and connected equipment, and pose a safety risk.
5. Інструкцыя па эксплуатацыі
Once properly installed and powered, the Legrand Emdx3 meter will begin measuring energy consumption. The display provides real-time data and accumulated values.
5.1 Навігацыя па дысплеі
The meter typically features buttons on the front panel for navigating through various display screens. These screens may show:
- Total active energy (kWh)
- Total reactive energy (kvarh)
- Імгненны абtage (V) per phase
- Instantaneous current (A) per phase
- Instantaneous active power (kW)
- Каэфіцыент магутнасці
- Частата (Гц)
Consult the specific product documentation for detailed instructions on button functions and display modes, as these can vary slightly between firmware versions.
5.2 Reading Data
The primary function is to display accumulated energy. For billing purposes, record the total active energy (kWh) reading at specified intervals. The MID certification ensures the accuracy of these readings.
6. Тэхнічнае абслугоўванне
The Legrand Emdx3 energy meter is designed for long-term, maintenance-free operation. However, periodic checks are recommended.
- Уборка: Clean the exterior of the meter with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Візуальны агляд: Periodically inspect the meter and its connections for any signs of damage, loose wiring, or overheating.
- Няма частак, якія абслугоўваюцца карыстальнікам: The device contains no user-serviceable parts. Do not attempt to open or repair the meter. Refer all servicing to qualified Legrand service personnel.
7. Выпраўленне непаладак
If the energy meter is not functioning as expected, consider the following common issues:
| праблема | Магчымая прычына | Рашэнне |
|---|---|---|
| Няма дысплея/няма харчавання | No power supply to the meter; loose connections. | Check circuit breaker. Verify all voltage and auxiliary power connections are secure. |
| Няправільныя паказанні | Incorrect CT wiring (polarity/phasing); incorrect CT ratio settings (if configurable); faulty CTs. | Verify CT connections and polarity. Ensure CT ratio settings match the installed CTs. Consult a qualified electrician. |
| Meter not responding | Internal fault; temporary software glitch. | Cycle power to the meter (turn off and on). If the problem persists, contact Legrand support. |
For issues not covered here, or if troubleshooting steps do not resolve the problem, contact Legrand technical support or a qualified electrician.
8. Тэхнічныя характарыстыкі
- Нумар мадэлі: 412043
- Марка: Легран
- Тып: Three-Phase Energy Meter
- Бягучы ўвод: P/Ti 5A (via external Current Transformers)
- Адпаведнасць: MID (Measuring Instruments Directive)
- Памеры (Д х Ш х У): 10 х 10 х 15 см
- Вага: 500 грамаў
- вытворца: Легран
- Неабходныя батарэі: няма
- Колькасць тавараў: 1
9. Гарантыя і падтрымка
Legrand products are manufactured to high standards and are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Legrand webсайт.
For technical assistance, troubleshooting, or service inquiries, please contact Legrand customer support. Ensure you have your product model number (412043) and purchase details available when contacting support.